Chapter 1: Module Overview
1-3
User’s Manual Pub. 0300181-07 Rev. A
Section 1.5
Detailed Specifications
Table 1-1. Thermocouple Temperature Ranges
Specification
Description
Configuration
4/8 Channel of differential counter inputs 2/4 Channels of quadrature
encoding 2/4 Input enable Control lines
Input Modes
DC counter, AC flow meter
Voltage Range
AC 0-30 VP
5 VDC
12 VDC
24 VDC
VIL
-50 mV
1 V
3 V
5 V
VIH
+50 mV
3.5 V
9 V
13 V
Vmax (CE)
±75 V
±75 V
±75 V
±75 V
Vmax (UL)
±100 V
±100 V
±100 V
±100 V
Current Range
5 mA maximum at 120 V
Input Impedance
Rin greater than 10 ohms when within -10 V to +12 V range.
Rin = 25 Kohms when outside of -10 V to +12 V range
Cin 100 pF
Input Filter Off
Cin 1000 pF Input Filter On
Counter Speed
DC Inputs
0 Hz to 50 kHz
AC Inputs
0 Hz to 50 kHz
Input Frequency
DC Inputs
1 Hz to 50 kHz
AC Inputs
1 Hz to 50 kHz
Counter Enable Input
VIL
1.0 V maximum
VIH 3.5 V minimum
Vmax 75 V
Input impedance
25 Kohms
Input Filter:
Digital Filter
Digital Filter
Analog Filter
50 kHz (Default)
30 kHz
15 kHz
Min Pulse Time:
DC mode
External Enable/Disable
8 us
Enable and Disable setup time = 20 us
Channel Update Time:
Counter Output
Rate Output:
Rate Instantaneous Mode
Rate Average Mode
Scaling OFF ON
4.00 5.6 (msec per channel)
4.00 5.6 (msec per channel)
1.00 1.00 (sec per channel)
Содержание SLC 500
Страница 1: ...User s Manual Pub 0300181 07 Rev A ...
Страница 8: ...viii SLC 500 50 kHz Counter Flowmeter Input Module User s Manual Pub 0300181 07 Rev A ...
Страница 24: ...2 10 Chapter 2 Installation and Wiring User s Manual Pub 0300181 07 Rev A ...
Страница 55: ...Chapter 6 Testing Your Module 6 5 User s Manual Pub 0300181 07 Rev A ...
Страница 56: ...6 6 Chapter 6 Testing Your Module User s Manual Pub 0300181 07 Rev A ...
Страница 60: ...7 4 Chapter 7 Maintaining your Module and Ensuring Safety User s Manual Pub 0300181 07 Rev A ...
Страница 64: ...A 4 Appendix A Floating Point Rate Mode User s Manual Pub 0300181 07 Rev A ...
Страница 65: ...User s Manual Pub 0300181 07 Rev A ...