![Spectron BE56-2U-VCR Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/spectron/be56-2u-vcr/be56-2u-vcr_user-manual_1344154029.webp)
Spectron Gas Control Systems GmbH
Dismantling and disposal | 11
GES_BE56-2U-VCR_1020
29
11 Dismantling and disposal
11.1 General information on dismantling
WARNING
Noise emission
When working on pressurised pneumatic supply, significant noise emission can occur. Acute
and chronic loss of hearing may result.
a) Never perform work on the pressurised pneumatic supply without hearing protection.
b) Only replace the silencers when the supply is unpressurised.
CAUTION
Injury or damage in the event of incorrect assembly or disassembly
Special steps are required for assembly and disassembly work on the product. Personal injuries
and damage to the product are possible.
a) Assembly and disassembly work may only be carried out by the installation engineer or ap-
propriately skilled specialist companies and persons.
b) The product is not permitted to be re-used following disassembly. All components must be
disposed correctly.
NOTICE
Lighting
Incorrect switching actions or confusion can occur due to inadequate lighting.
a) Ensure sufficient lighting in accordance with the statutory regulations.
Before dismantling and disposal of the pressure control panel, it must be taken out of operation
and purged. The pressure control panel must then be disconnected from the auxiliary media
supply.
The dismantling process is to be carried out in the following order:
1. Purging of the pressure control panel and decommissioning.
2. Disconnect the pressure control panel from the gas supply system.
3. Disconnect the pressure control panel from the process.
4. Remove the pressure control panel – to do so, please refer to the "
chapter.
5. Seal all ports on the pressure control panel.
6. Pack the pressure control panel.