Mechanical Specifications
40
SafEye
TM
Xenon 700S Gas Detector User Guide
4.2.4.4
HART Protocol
The HART Protocol is a digital communication signal at low levels in addition
to the 0–20mA.
This a bi-directional field communications protocol used to communicate
between intelligent field instruments and the host system.
Through the HART Protocol the detector can:
Display setup
Reconfigure setup
Display detector status and definition
Perform detector diagnostics
Troubleshoot
Mechanical Specifications
4.3
Enclosure:
The detector, source, and tilt mount are St. St.
316 Electro chemical and passivized coating
Explosion Proof:
IECEx Ex II 2(1) G,
Ex d e ia [ia Ga] IIC T5 Gb
Ta -40°F/-40°C to 131°F/55°C
Water and Dust
Tight:
IP 66 and IP 67
NEMA 250 type 6p
Electrical Modules:
Conformal coated
Electrical
Connection:
(Two options - specified at time of order)
2 X M25 (ISO)
2 X 3/4” - 14NPT conduits
Dimensions:
Detector 8.2 x 5.7 x 6”
210 x 145 x 154 mm
Source
10 x 5.3 x 6.9”
255 x 135 x 175 mm
Tilt Mount 4.7 x 4.7 x 5.5”
120 x 120 x 140 mm
Weight:
Detector
9.2lb
4.2kg
Source
10.1lb
4.6kg
Tilt Mount 4.2lb
1.9kg
Содержание SafEye Xenon 700S
Страница 2: ...This page intentionally left blank ...
Страница 12: ......
Страница 16: ......
Страница 24: ...Models and Types 24 SafEyeTM Xenon 700S Gas Detector User Guide Figure 1 Wiring Options ...
Страница 64: ......
Страница 72: ......
Страница 76: ......
Страница 79: ...This page intentionally left blank ...