background image

page 7 of 12

Pairing handheld transmitter & controller

The handheld transmitter is already paired in the factory and ready 
to use. The PL-REM-P can pair with up to 6 handheld transmitters. In 
case a problem arises, the pairing process can be done manually:

Manual Pairing process:

Make sure the PL-REM-P is connected to a power source. 
1.  Press the pairing button on the small circuit board, inside the con-

troller for at least 5 seconds.

 

--> The LED will start to blink fast

2.  Within 25 seconds, press any button on the handheld transmitter. 

 

--> If the transmitter is paired correctly, the LED will flash slowly for 5 times 

 

--> If the PL-REM-P pairing memory is full, the LED will flash 15 times.    

               This means 6 handheld devices have already been paired.

To unpair all handheld transmitters with the controller: Push the pair-
ing button for at least 5 seconds, then do nothing for at least 25 sec-
onds.
 

--> The pair memory will be erased - the red LED will flash 5x on/off.

Red LED

Pairing button

Содержание PL-REM-P

Страница 1: ...LED pool light Remote Control OWNER S MANUAL PL REM P Controls Spectravision Pool Lights and 2 auxiliary circuits Long range DuraLink version ...

Страница 2: ...ecifications Box contents Installation instructions Pairing Handheld Transmitter controller Handheld transmitter functions Replacing transmitter battery Troubleshooting Page 3 Page 4 Page 5 6 Page 7 Page 8 Page 8 Page 9 page 2 of 12 ...

Страница 3: ... 0 C 40 C 10 90 RH non condensing 150x157x51 mm 500 g IP54 Nominal Input voltage Max rating Relay Contacts Color Light A and B Resistive Load Inductive Load Frequency band transmitter IEC Protection Class 230 VAC 50 Hz 14A 250VAC 14A 30VDC 6A 250VAC 6A 30VDC 868 MHz Class II For operation only with 12VAC safety isolation transformer to power Spectravision LED Pool Lights ...

Страница 4: ...page 4 of 12 Box contents 1 2 4 5 1 PL REM P controller 2 Handheld transmitter DuraLink version 3 Spare battery type A23 12V 4 Screws 4x wall plugs 4x 5 Owners s manual 3 ...

Страница 5: ...0 240VAC INPUT terminal Connect the primary circuit of a 12VAC transformer sold sepa rately in series with the Color Light terminal of the PL REM P The Color Light relay contact has an output of 14A which can drive a 12V transformer of max 3000W 220Vx14A Optional The Switch A switch B terminals can be used to control auxiliary circuits like a pool cover or garden lights ...

Страница 6: ... arately in series with the Color Light terminal of the PL REM P The Color Light relay contact has an output of 14A or 170W on a 12V transformer secondary 14Ax12V The total load of pool lights can not exceed this Optional The Switch A switch B terminals can be used to control auxiliary circuits like a pool cover or garden lights 230VAC Garden lights Pool cover 230VAC 230VAC 12VAC ...

Страница 7: ...oard inside the con troller for at least 5 seconds The LED will start to blink fast 2 Within 25 seconds press any button on the handheld transmitter If the transmitter is paired correctly the LED will flash slowly for 5 times If the PL REM P pairing memory is full the LED will flash 15 times This means 6 handheld devices have already been paired To unpair all handheld transmitters with the control...

Страница 8: ...8 of 12 Toggle the lamps ON OFF Go to next color scenario Pulse Output A Pulse Output B Replacing transmitter battery Remove the philips head screw and open the transmitter Replace the battery respecting the polarity Battery type A23 12V ...

Страница 9: ...epeat the pairing process Reduce the distance between handheld transmitter and PL REM and or remove obstacles The pool lights don t work Check if all connections are made according to the electri cal scheme on page 5 or 6 Check if the Color Light out put terminals of the controller switch on and of when pushing the on off button on the trans mitter Troubleshooting page 9 of 12 ...

Страница 10: ...uencies between 9 kHz and 25 GHz EN 301 489 3 Electromagnetic compatibility and Radio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 3 Specific conditions for Short Range Devices SRD operating on frequencies between 9 kHz and 40 GHz Equipment handheld transmitter receiver for remote control base unit transmitter receiver 868MHz band DuraLink T...

Страница 11: ...page 11 of 12 ...

Страница 12: ...vba Dooren 72 1785 Merchtem Belgium Tel 32 2 461 02 53 Fax 32 2 706 59 60 www propulsionsystems be info propulsionsystems be We reserve the rights to change all or part of the contents of this document without prior notice 402 0032 150630 ...