SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
13
FEED SUPPLY INSTALLATION
FEED SUPPLY VALVE INSTALLATION
STEP 1. Follow the cold water line from shutoff valve to the existing faucet and unscrew the threaded connection.
STEP 2. Insert feed supply valve between cold water line and existing connection.
STEP 3. Follow the assembly sequence shown for attaching valve to the existing cold water line.
STEP 4. Connect Black line from RO system as shown in Fig 1.
a. Remove the 1/2" Compression Nut from Valve body. Be careful not to loose the plastic or brass Insert
and the Conical Compression Sleeve.
b. Insert the 1/4" Black Tubing into the Compression Nut with the threads towards the end of the tube.
c. Slip the Conical Compression Sleeve onto the Black Tube with the long slope pointing toward the end
of the tube.
d. Place the Insert into the end of the Black Tubing. Make sure you push the insert in all the way.
e. Tighten Compression Nut back on the Valve body.
STEP 5. When installation of the valve is complete, check for leaks as follows:
a. Close Feed Supply Valve that you just installed.
b. Open cold water supply valve and check for leaks around feed supply valve fittings. Tighten if necessary.
NOTE: To be certain of the cold line; turn on the hot water, allow water to run until pipe becomes warm. Then
attach fitting to the cold water line. If you run hot water through your system it will damage the membrane.
INSTALL ON COLD WATER LINE
FEED VALVE