background image

Technical Bulletin CS-07-05 

         Part 

3867-36075-001 

The information provided in the SpectraLink technical bulletin is provided "as is" without warranty of any kind.  No obligation or liability will 
arise out of, SpectraLink rendering technical or other advice or service in connection herewith.                                                          Z-0041-00 

TECHNICAL BULLETIN CS-07-05 

NetLink 8000 Handset Software on a NetLink Gateway 

Notification Date: 

9/18/07 

Originator:

 Josh 

Redmore 

 

 

 

 

 

 

 

 

 

Effective Date: 

9/18/07 

Approvers

Wayne McAllister (VP Cust. Svc) 

 

 

 

 

 

 

 

 

    Mark Hamilton (VP S/W Dev.) 

Systems Affected: 

NetLink  

Hardware Affected

: NetLink 

Gateways 

Status: 

Approved

 

Access Level: 

General

 Revision: 

B

 

Summary: 

An “Undefined Error: 0” is received when attempting to FTP 8000-series handset software to a NetLink 
Gateway. 

Description: 

When attempting to load 8000-series handset software to a Gateway’s internal TFTP server, a user may 
see an error of “553 Can’t create <filename>: Undefined error: 0”.  The user will then be unable to use the 
Gateway to distribute the upgraded software to the handsets 

Resolution: 

Any NetLink environment using 8000-series handsets must use an external TFTP server for handset 
software upgrades. 