14215700-IG, Edition 7.0
January 2018, Original document
215
Field
Base Station - Synchronization
Type
This setting controls the synchronization type used for the
specific base station/DECT radio.
Possible values:
Free running
,
Radio
,
LAN
or
Radio/LAN
Gateway
.
Select
Free running
, if you want to configure this base sta-
tion as sync master. Otherwise select either
Radio
,
LAN
or
Radio/LAN Gateway
, depending on the synchronization
method.
Default value: Radio
Note
: System wide settings for synchronization are located
under
Configuration
>
Wireless Server
>
Base stations
.
For more information, see Synchronization and Deployment
Guide.
Auto radio sync (deployment only)
(Optional)
If enabled, the base station will be auto synchronized while
deploying the system.
Note
: This must only be used while deploying the system.
Primary radio sync (RPN)
(Optional)
RPN identifying the base station used for primary radio syn-
chronization.
Secondary radio sync (RPN)
(Optional)
RPN identifying the base station used for secondary radio
synchronization.
Base Station - RSSI map
(Only visible if more than one base station on the system)
RPN/RSSI dB/Offset
Possible to see the RSSI values of the base stations the
selected base station is synchronizing on (Primary syn-
c/Secondary (Alternative) sync).
For more information about RSSI values, see Syn-
chronization and Deployment Guide.
Administration - Clusters - Cluster 0
Field
Cluster - General
Name
Enter a name for the cluster.
E.g. Site A, Site B, Site C.
Spectralink IP-DECT Server 400/6500 Installation and Configuration Guide