The correct cable to use is a USB Series ’A’ male to USB
Series ’B’ male. Specified maximum USB cable length for
Low-Speed peripherals is 3-meters (9.84 ft.).
4.5
Incoming Confidence Check
The following information concerns the model 2241/2241A with Record-R function and is in
addition to the checks detailed previously in this document. Turn on power. The three LEDs next
to the Record-R pushbutton alternately turn ON and OFF in the following order:
Pushbutton Name Function
1. ‘GPS LOCK’ on
2. ‘GPS LOCK’ and ‘MEMORY OK’ on
3. ‘GPS LOCK’ , ‘MEMORY OK’ and Record-R on
4. ‘GPS LOCK’ off; ‘MEMORY OK’ and Record-R on
5. ‘GPS LOCK’ and ‘MEMORY OK’ off; Record-R on
6. All three OFF,
7. ‘MEMORY OK’ on (to indicate room in memory, if
available) and the ‘GPS LOCK’ LED will pulse once
every four seconds to indicate the receiver is
attempting to acquire satellites.
4.6
Operating Procedures
The following paragraphs describe the procedures for recording data using the Record-R
function on the PathAlign-R and downloading and saving logged data using the LogView-R Data
Log Utility software and a PC computer.
4.6.1 Recording Data
When the [Record-R] button on the PathAlign-R is pressed, an individual data record is created
and stored in the instrument’s memory. The memory used for this storage is non-volatile; it is
not affected by turning the instrument off. The information stored includes the instrument’s
model number, serial number, date and time, location (latitude and longitude), frequency in use
and the measured path loss. The LogView-R utility allows you to access this, save all of the
data records to a disk file and save individual data records to separate disk files. The data files
generated are in a format suitable for importing into a spreadsheet program (.CSV).
4.6.2 Connecting a Computer to the PathAlign-R
Prior to connecting the instrument to a computer the LogView-R Data Logging Utility needs to
be installed in the computer because the USB drivers that Windows needs are located on the
utility disk.
The PathAlign-R can be connected to any Windows computer containing an RS-232 or USB
port. When the instrument is connected to a PC computer through the USB port, the instrument