If you make a mistake, the keypad will emit a Rejection Beep. When you have correctly Stay Armed the system, the appropriate
ARM
or
STAY
indication appears and the Exit Delay is initiated. Stay Arming can also be activated using Auto-Arming, Keyswitch
Arming or One-Touch Arming. The User Code must have the Stay Arming Option enabled.
13.6 INSTANT ARMING
After Stay Arming
the system and
during its Exit Delay,
press and hold the
[
STAY
]
key for 3 seconds
.
You should hear a
Confirmation Beep. This will switch all armed zones to Instant zones.
If you have access to both partitions:
To Instant Arm one partition, press
[
STAY
]
+
[
ACCESS
CODE
]
+ Select Par
[
CLEAR
]
+ press & hold
[
STAY
]
To Instant Arm both partitions, press
[
STAY
]
+
[
ACCESS
CODE
]
+
[1]
+
[2]
+ press & hold
[
STAY
]
13.7 FORCE ARMING
(NOT TO BE USED WITH UL INSTALLATIONS)
Force Arming allows users to rapidly arm the system, without having to wait for all zones in the system to be closed. Force
Arming is commonly used when a motion detector is protecting the area occupied by a keypad. Therefore, when arming the
system, if the motion detector is set as a Force Zone, the control panel will ignore the zone and allow users to arm the system
even if the zone is open. Any open Force Zones at the time of arming will be considered deactivated by the control panel. If
during this period a deactivated zone is closed, the control panel will revert that zone to active status, hence, will generate an
alarm if breached.
If you make a mistake, the keypad will emit a Rejection Beep. When correctly Force Armed, the appropriate arm indication
appears and the Exit Delay will initiate. Please note that Force Arming can also be activated using One-Touch Force Arming.
Also, note that the User Access Code must have the Force Arming Option enabled.
13.8 MANUAL BYPASS PROGRAMMING
Manual Bypass Programming allows users to program the alarm system to ignore (deactivate) specified zones the next time the
system is armed. The
Access Code
must have the Bypass Programming Option enabled. Please note that Fire Zones cannot be
bypassed. Manual Bypass Programming can also be activated using One-Touch Bypass Programming.
13.8.1
B
YPASS
R
ECALL
F
EATURE
After disarming the system, the control panel will erase the bypass entries. By using the Bypass Recall Feature, you
can reinstate the previous bypass entries saved in memory. This eliminates the need to manually program the bypass
entries every time you arm the system. The Access Code must have the Bypass Programming Option enabled.
13.9 ONE-TOUCH ARMING
One-Touch Arming allows users to arm the system without using an access code. Simply press and hold a key. One-Touch
Arming can be used to allow specific individuals like service personnel (i.e. cleaners, maintenance) to arm the system when
How Do I Force Arm?
1)
All zones in the desired partition (except Force Zones) must be closed.
2)
Press the
[
FORCE
]
key.
3)
Key in a valid
[
ACCESS
CODE
]*
.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the partition you wish to Force Arm
.
To arm both partitions, press the
[1]
key then after the
Confirmation Beep press the
[2]
key.
How do I Program Bypass Entries?
1)
Press the
[
BYP
]
key.
2)
Key in a valid
[
ACCESS
CODE
]
*
.
3)
Select one or more
[
ZONES
]
you wish to bypass.
4)
Once you have entered the desired bypass entries, press the
[
ENTER
]
key to accept these entries.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the desired partition
.
How Do I Recall Bypass Entries?
1)
Press the
[
BYP
]
key.
2)
Key in your
[
ACCESS
CODE
]*
.
3)
Press the
[
BYP
]
key.
Previously bypassed zones will illuminate.
4)
Press the
[
ENTER
]
key.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the desired partition
.