background image

 

This document is for informational purposes only and is not a legally binding agreement or offer. 

Spectra Precision makes no warranties and assumes no obligations or liabilities hereunder.

 

Spectra Precision, 10355 Westmoor Drive, Suite #100, Westminster, CO 80021, USA 

© 2009, Spectra Precision. All rights reserved. Spectra Precision and the Spectra Precision logo, and EPOCH are trademarks of Spectra Precision, registered in the United 
States and in other countries. Nomad and Recon are either trademarks or registered trademarks of Tripod Data Systems, Inc. Microsoft and Windows are either registered 
trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other trademarks are the property of their respective owners.

 

www.spectraprecision.com 

Page 1 

 

December 2009

 

 

Spectra Precision EPOCH 35 GNSS System 

This document outlines the basic procedures for updating EPOCH 35 GNSS 
firmware.  This document covers ONLY how to update the GNSS firmware, 
which is separate and distinctly different than updating the MPU firmware. 
 

Required: 

67410-xx EPOCH 35 Receiver  
54344-10 Battery (fully charged) 
59046-10 Instrument cable 
WinLoad Firmware loading software 
 

Procedure 

1)

 

Download the firmware update file from the Partners website  

2)

 

Extract the firmware update file to a directory on the computer you will use for the updates 

a.

 

The firmware update file includes the firmware, loading scripts, a database of all 
licensed GNSS boards, and the WinLoad firmware loading software 

3)

 

Use the EPOCH 35 Service Software to verify the GNSS board firmware version number. Do 
not reload the same version of firmware.  

4)

 

Prepare WinLoad 

a.

 

Check for a more current version of the 3620.hex file on Spectra Partners or web site 

i.

 

If a newer file is available, download it and place it in the WinLoad directory 

b.

 

Double click on WinLoad.exe to launch the program 

c.

 

Click on File | Open File 

i.

 

Select 3620.hex from the X.xxx Update Disk directory (where X.xxx is the 
version number of the firmware you are loading) 

ii.

 

The Write Flash and Query Card buttons will become active once the hex file is 
loaded. 

d.

 

Click on Settings | Com Settings… 

i.

 

Insure the Com Port is set to the COM port of your PC that the instrument cable 
will be connected to 

ii.

 

Insure the Download Baudrate is set to 115200 

iii.

 

Insure the Connect Baudrate is set to 9600 

iv.

 

Click OK to close the Com Port Setup dialog box 

Отзывы: