Spectra 20K/64K Library AIT-4 Drive Upgrade

4

Replacing Drives

Moving Original Drives Off-line

1.

On the Library Controller, select 

Toolbars -> General.

 The General toolbar 

displays.

2.

Select 

Drive Config

. The Drive Configuration screen appears Figure 2.

3.

Select the drive you want to replace, the select 

Replace

. A dialog box series 

displays, first asking whether it is 

Okay to Replace Drive? 

then

 “Are you sure 

you want to open the door?

 

4.

Select Okay for each. This powers down the drive and disengages the solenoid 
latches on the front door. A dialog box displays the message 

Open Door and 

Replace Drive

Close and Latch Door

Tap Okay when complete

Note:

Do 

not

 select 

OK 

until you have completed the procedure.

Figure 2 

The Drive Configuration Screen.

Содержание AIT-4

Страница 1: ...ns on page 6 Preparation 1 Identify the drives to be upgraded in your Spectra 20K 64K library 2 Make sure you have an AIT 4 drive for every drive you are replacing and a library firmware upgrade diske...

Страница 2: ...LCM 3 Follow on screen directions inserting disks one at a time until operation is complete 4 Remove all disks and reset the LCM The operating system and Library Controller will now be upgraded 5 The...

Страница 3: ...rmware Update screen displays Figure 1 3 In File Locations select Local Directory Select Location then select the most recent firmware package 4 Select Update Firmware The library firmware update proc...

Страница 4: ...want to replace the select Replace A dialog box series displays first asking whether it is Okay to Replace Drive then Are you sure you want to open the door 4 Select Okay for each This powers down th...

Страница 5: ...ller then select OK The library processes this change and may require a few minutes to complete When the drive has been configured another statement displays The library geometry has changed Reloading...

Страница 6: ...ed data and run a restored program Refer to your backup software documentation for a more specific procedure After you have performed a drive test successfully continue 2 Restart backup processes Sony...

Страница 7: ...ary depends on the number of drives installed in the library c The sustained transfer rate can increase by an average of 2 6 times with compression dependent on the type of data 3 MB sec native 6 MB s...

Страница 8: ...Spectra 20K 64K Library AIT 4 Drive Upgrade 8...

Отзывы: