Speco PL-60 SA Скачать руководство пользователя страница 1

CAUTION: TO REDUCE THE RISK 
OF ELECTRIC SHOCK, DO NOT 
OPEN COVER. NO USER 
SERVICEABLE PARTS INSIDE. 

REFER SERVICING TO QUALIFIED 

SERVICE PERSONNEL.

WARNING: REMOVAL OF THE 

COVER SHOULD ONLY BE PER- 

FORMED BY QUALIFIED SERVICE 
PERSONNEL - NOT USER SER- 
VICEABLE. THE UNIT SHOULD 

ALWAYS BE UNPLUGGED BEFORE 

REMOVING THE COVER, AND 
REMAIN UNPLUGGED WHILE THE 

COVER IS REMOVED.

WARNING: TO PREVENT FIRE 
OR SHOCK HAZARD, DO NOT 

EXPOSE UNITS NOT 

SPECIFICALLY DESIGNED FOR 
OUTDOOR USE TO RAIN OR 

MOISTURE.

INSTRUCTION
MANUAL

PUBLIC ADDRESS
AMPLIFIER

PL-120 SA

PL-60 SA

    RISK OF ELECTRIC 

SHOCK, DO NOT OPEN!

60 WATT RMS X 2

30 WATT RMS X 2

200 NEW HIGHWAY, AMITYVILLE, NY11701

PHONE : 1-800-645-5516, 631-957-8700 IN METRO NY
http://www.specotech.com

1.Unpacking

After removing the amplifier from the carton, inspect for any exterior damage to
the unit. If damage is noted, notify the carrier at once so that a claim can be
justified. Save all packing material. This is important when the claim is 

processed.

PRECAUTIONS

2.Ventilation

To offset heat generated by the unit, it is necessary to provide ample ventilation
around the unit. Avoid blocking or impeding the ventilation holes on the unit. To

prevent unnecessary problems, install the unit in a place free from any 

vibrations, direct sunlight, humidity or dust circulation.

3.Avoid spilling liquids or allowing materials to enter the  

   cabinet

If the unit gets wet or any foreign material enters the cabinet, immediately

disconnect the A.C. line cord and consult your dealer or qualified technician.

 

Содержание PL-60 SA

Страница 1: ...NE 1 800 645 5516 631 957 8700 IN METRO NY http www specotech com 1 Unpacking After removing the amplifier from the carton inspect for any exterior damage to the unit If damage is noted notify the carrier at once so that a claim can be justified Save all packing material This is important when the claim is processed PRECAUTIONS 2 Ventilation To offset heat generated by the unit it is necessary to ...

Страница 2: ...ted to the apparatus 11 Only use the attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14...

Страница 3: ... 8 TEL PAGING output level control 9 MIC VOX on off switch MOH Music on hold TEL PAGING Connection input terminals for general or emergency paging TEL PAGING is not to be connected directly to a telephone circuit or TNV circuit 7 Bass Control 8 Treble Control 9 Balance control 10 MASTER Volume 11 Power on off switch with Lamp indicator 12 Output level indicator 10 MIC output select switch L L R R ...

Страница 4: ...minals Provides contact closure muting of the AUX 1 2 input during paging 6 TEL PAGING balanced input terminals Accepts a balanced telephone paging signal 7 TEL PAGING output select switch L L R R Select output signal mode of TEL PAGING 8 TEL PAGING input level control Controls audio level of telephone input 9 MIC VOX on off switch MIC inputs include VOX muting switch during paging 10 MIC output s...

Страница 5: ...ICIAN TO ACCOMPLISH THIS TO AVOID POTENTIAL PERSONAL INJURY OR A HAZARDOUS CONDITION SPEAKER CONNECTION The rear panel of the amplifier contains a 4 screw terminal strip for R and L speaker connection BE SURE TO CONNECT SPEAKERS PROPERLY see line voltage instructions below The speaker lines are to be connected directly between the appropriate COM terminal on the 4 screw terminal strip and the term...

Страница 6: ...e the preferred method for multi speaker installation CABLE REQUIREMENTS Output cabling need not be shielded in most cases and should be of sufficient gauge to minimize losses due to the resistance of the wire over long runs insertion loss Cable thinner than 18 gauge is not recommended Long runs require 16 gauge or heavier In some cases where the output cable is run in close proximity to unshielde...

Страница 7: ...prior to removing unit s cover or electrical shock or injury may result The unit provides a Phantom Power DC 15V for condenser microphone Jumper location is to enable ON or disable OFF Phantom Power feature Note Units come with Phantom Power enable ON Jumper location to select AUX input for music on hold output MOH on above diagram Note Units come with jumper set on AUX 1 ...

Страница 8: ... 70 dB MIC Better than 60 dB TEL Better than 60 dB AUX 1 2 Better than 70 dB Speaker outputs 70V Stereo line outputs 70V Stereo line outputs AUX output 350mV 600 Ohm 350mV 600 Ohm MOH output 600 Ohm 1V and 8 Ohm 1Watt 600 Ohm 1V and 8 Ohm 1Watt Mute level AUX 1 2 40 dB AUX 1 2 40 dB Phantom Power MIC 16 V DC 16 V DC Tone control Bass 10 dB at 100Hz Treble 10 dB at 10KHz Bass 10 dB at 100Hz Treble ...