Low Tonnage Gauge Kits for Atlas™ Manual Hydraulic Presses
13
Now, still with the valve tap (
79
) closed, follow the procedure to adjust
the
pressure relief valve assembly
on the press to set a maximum
tonnage load achievable on the press that corresponds to the
maximum load capability of the low tonnage gauge (
75
) as fitted.
(1 ton, 2 tons or 5 tons range.) The procedure to adjust the pressure
relief valve is found in the user instruction manual for the Atlas™
manual hydraulic press.
Switching On and Off the Low Tonnage Gauge
To bring the low tonnage gauge “on line” for load reading, the valve tap
(
79
) on the manifold body (
77
) is opened. (
79
) is a needle type valve
(See
Fig 6.
) and the tap handle only needs
a quarter to half turn
maximum
anti-clockwise to open for the low tonnage gauge (
75
) to be
switched on to register a tonnage load.
Beware:
If the valve tap (79) is opened too far from turning the handle
anti-clockwise for operation of the low tonnage gauge, there
is a risk that the O-ring (80) will not seal effectively and so oil
pressure in the system will be lost and there will be no
effective build-up of a tonnage load that can be applied to any
work/sample being held in the press.
The following table shows the situation relating to which gauge is
working when the pressure release valve (
30
) on the press and the
valve tap (
79
) on the manifold body (
77
) are either open and/or closed.
Valve
Status of Valve
Gauge Being Used
(30)
(79)
Open
Open
Neither
(30)
(79)
Closed
Open
(31)
(75)
(30)
(79)
Closed
Closed
(31)
(30)
(79)
Open
Closed
Neither
Содержание GS15051
Страница 1: ...Low Tonnage Gauge Kits for Atlas Manual Hydraulic Presses User Manual 2I 15051 8...
Страница 2: ......
Страница 3: ...Low Tonnage Gauge Kits for Atlas Manual Hydraulic Presses User Manual 2I 15051 8...
Страница 17: ...Notes for Use of Low Tonnage Gauge Kit...
Страница 18: ...Notes for Use of Low Tonnage Gauge Kit...