Speakman SM-Regency Series Скачать руководство пользователя страница 1

PAGE 1                                                                                                                                                                        02/10 

                                                                                                                                                                          92-3098 R-1  

 

SPEAKMAN COMPANY

 

SM- Regency/Royale Valve, Showerhead, Tub Spout, & Combo Series 

Installation, Maintenance & Operation Instructions

 

DESCRIPTION 

Speakman Sentinel Mark II Regency/Royale concealed anti-scald balanced pressure shower /bath valve & combinations. Chrome 
plated brass wall plate (Regency). Chrome plated plastic wall plate (Royale). Chrome plated brass lever handle. Adjustable 
temperature limit stop. Brass body. Piston type pressure balancing/ceramic regulating cartridge assembly with built-in check 
valves. Can be installed back to back. Roughing-in template. S-2270-AF COSMOPOLITAN® showerhead (If applicable), S-
2280-AF Anystream wall mounted showerhead (If applicable), or VS-100 Handheld Shower (If applicable) with flow control 
device reduces flow to 2.5 GPM/9.46 LPM maximum to meet existing ASME A112.18.1/CSA B125.1 Standard. Chrome plate 
brass shower arm and wall flange (If applicable). Chrome plated tub spout (If applicable). Four port valve with ½” female copper 
sweat inlets and shower outlet. ½” NPT female tub outlet. Meets ASME A112.18.1/CSA B125.1 & ASSE 1016 standards. 

SPECIFICATIONS 

 SUPPLY: ½” FEMALE COPPER SWEAT INLETS & SHOWER OUTLET; ½” NPT FEMALE TUB OUTLET (VALVE) 
 FLOW RATE: 2.5 GPM/9.46 LPM MAX. (SHOWERHEAD AND/OR HANDHELD SHOWER, IF APPLICABLE) 
 SHIPPING WEIGHT: 3.5 LBS (SM-3000) 

OPTIONS 

 

INSTALLATION INSTRUCTIONS 

Important- 

Read these instructions before installing the valve. Use the correct “Rough-in Diagram” for the unit that is being 

installed. Maximum water pressure: 125 PSI static; minimum water pressure: 20 PSI flowing; maximum supply temperature: 160° F; 
minimum supply temperature: 40° F. Use a suitable sealant on all threaded connections and when soldering, it is recommended to 
remove the integral stop valve parts (If applicable) and VC/DIV cartridge (If applicable). The valve rough-in adjustments are 2-1/2” 
to 3-1/2” from the finished wall to the centerline of the hot & cold inlets of the valve body.  
1)

 

Referring to the correct “Rough-in Diagram” for the unit that is being installed 
(See the back page or the separate insert sheet), install the hot & cold supply 
lines for the valve, making sure they are on an accurate horizontal plane. 
Taking the valve assembly, making sure the “UP” on the valve bonnet is in the 
up position, connect the hot supply line to the left side of the valve & the cold 
supply line to the right (marked “BLUE”) side of the valve. Make sure the 
valve is straight, level, & positioned properly in the wall (See Figure 1). See 
Page 2 for “Back-To-Back” valve installation instructions. 

2)

 

Slip the rough-in template over the valve control spindle. If the opening in the 
wall is smaller then the outside diameter of the template, trace the outside 
diameter of  the template, remove the template, and recut the opening in the 
wall. Slip the template onto the valve again until the template bottoms out on 
the top of the valve bonnet (See Figure 2). Note- When installing a valve with 
the built-in volume control/diverter feature, make sure the template is 
positioned so the brass “VC/DIV” spindle is in the relieved area of the 
template. The finished wall should fall between the minimum and maximum 
limits of the template if the valve has been installed properly. Leave the 
template in place if the finished wall has to be installed. The template will 
insure the proper size opening for repair accessibility, as well as protect the 
valve from damage during the finished wall installation.    

3)

 

 Install the rough piping and transfer valve (If applicable) to the shower and/or tub outlets of the valve. If the installation is 
only using one outlet, be sure to plug the other outlet with the provided pipe plug. Check connections for leaks. If applicable, 
construct the finished wall. 

 

1 -

 S-2251 Showerhead

 

 

4 -

 S-2220-AF Showerhead

 

 

AP - 

Anchor Plate (S-2280-AF 

Showerhead Only)

 

 

2 -

 S-2252-AF Showerhead

 

 

6 - 

S-2288-AF Showerhead

 

 

BJ - 

Ball Joint (S-2280-AF 

Showerhead Only)

 

2VR - 

S-2252-AF Vandal 

Resistant  Showerhead 

 

 

PC – 

Polish Chrome Handheld 

Shower (Combo w/VS-100 Only)

 

VH- 

White Vinyl Hose (Combo 

w/Handheld Shower Only)

 

3 - 

S-2253-AF Showerhead

 

 

9 - 

S-2292-AF Showerhead

 

 

LH - 

Less Showerhead 

 

 

7 - 

S-2291-AF Showerhead

 

 

IS - 

Integral Stops

 

 

 