INSTRUCTIONS FOR MODELS

92-S-1496-LH-98-05

For additional assistance or service please contact:

SPEAKMAN

®

800-537-2107

[email protected]

www.speakman.com

S-1496-LH

S-1498-LH

HELPFUL TOOLS & SUPPLIES:

TOOLS AND SUPPLIES

Pencil

Adjustable

Wrench

Flat Tip

Screwdriver

Phillips

Screwdriver

Thread Seal

Tape

3/32" Hex Key Wrench

(Included)

Measuring

Tape

Safety

Glasses

Level

Warranty information can be found at: 

www.speakman.com

WARRANTY

Your new Shower/Bath Valve is designed for years of 

trouble-free performance. Keep it looking new by cleaning 

it periodically with a soft cloth. The use of harsh chemicals 

and abrasives on any of the Speakman custom finish 

products may damage the finish and void the product 

warranty. Please be sure to only use approved cleaners. 

Please contact Speakman for any clarification of 

acceptable cleaners.

This type of valve must be cleaned and maintained on a 

regular basis. Periodic maintenance should be performed 

at least every 12 months or after any changes have been 

made to the building’s plumbing system. Valves that are 

installed outdoors should be winterized by removing all of 

the internal parts and removing any standing water from 

the valve. Quarterly the maximum hot temperature setting 

(TLS) should be checked and adjusted accordingly. 

MAINTENANCE

Cover your drain to prevent loss of parts. Be sure to wear 
eye protection while cutting pipe.

SAFETY TIPS

IMPORTANT

• Be sure to read instructions thoroughly before  

   

beginning installation.

• Be sure to have properly adjusted the Temperature  
   Limiting Stop (TLS) as outlined in this Installation      
Manual.

• Inspect all connections after installation of valve.

• This valve has an operating range of 

20-80 Psi.

• This valve is designed to be used in conjunction      with 
a shower head rated at 

1.75 gpm (6.6 L/min)

  

   or 

higher flow rate.

• 

NOTE:

 This installation manual covers several      

models of valves. While the appearance of your  

   

valve may differ from those shown, the installation      
method is the same.

• 

Maximum water pressure: 125 psi static; minimum     

water pressure: 20 psi flowing; minimum cold     

   

supply temperature: 40 °F; maximum hot supply  

   

temperature: 160 °F.

FREEZE PROTECTION

Freeze damage to the shower unit will void the 

warranty. It is important to winterize the complete 

shower unit. The unit must be drained of all water 

in freezing conditions. This includes removing the 

valve cartridge and the shower head from the unit. 

Store the valve cartridge and shower head indoors.

• Mounting location must be capable of supporting the 
product in use.

CAUTION:

 When outdoor temperature

rises above 90 degrees, use caution to
prevent scalding from water stored within
the unit. It is recommended to flush the unit
by turning it on for 30 seconds before
entering the shower water. This will avoid
accidental scalding by the user and ensure
safe use of the shower unit.

1

Slide the Strap (1) onto the Shower Arm (2).

2

Apply Thread Seal Tape to both ends of Shower Arm Gooseneck, and Bottom Plug. Thread Shower Arm Gooseneck into Valve 
Body being sure to properly align outlet. Install Plug into bottom port of Valve Body and Wrench tighten.

HANDLE AND DIAL CAP REMOVAL

3

3/32"

The Handle and Dial Cap must be removed for proper mounting of the Shower Valve and to adjust the Temperature Limit Stop. 
Remove the Handle Screw (1), then slide the Handle (2) off. Remove the Dial Cap Screw (3) followed by sliding off the Dial 
Cap (4).

4

Mounting location of Shower Valve.

 

Determine mounting location of Shower Valve. (See 
Rough-In Diagram located at the end of this document).

Secure with Mounting Screws (not included) to structure 
capable of supporting the product in use. 

Ensure there is adequate distance between the Valve 
and mounting structure to allow for installation of Water 
Supply lines.

Note:

 A Spacer Block with a thickness of 1/2"-9/16" 

is required between the Shower Valve (1) and the 
Mounting Structure (2) only. This is to allow for adequate 
clearance while installing inlet supply lines.

5

Apply Thread Seal Tape to HOT and COLD Pipe 
Connections (not supplied). Install the HOT and COLD 
Pipe Connections to the Valve accordingly, either 
through the wall, from the ceiling, or from the floor. For 
ceiling and floor mounts, hold 1” from finished wall to 
center of supply lines. Thread
into Valve Body and Wrench tighten. 

Turn on water 

supply and check for leaks.

NOTE:

 Illustration shown is for reference only.