background image

INSTRUCTIONS FOR MODELS

92-SE-4330-01

For additional assistance or service please contact:

SPEAKMAN

®

 Company

400 Anchor Mill Road
New Castle, DE 19720

800-537-2107

[email protected]

www.speakman.com

SE-4330
GRAVITYFLO

Portable Eyewash
with Heated Jacket

HELPFUL TOOLS & SUPPLIES:

TOOLS AND SUPPLIES

Flat Tip

Screwdriver

Adjustable

Wrench

Socket

Wrench

Phillips

Screwdriver

Pencil

Level

Drill

Drill Bit

Measuring

Tape

Safety

Glasses

Slip Joint

Wrench

3 Year Limited Warranty
1 Year on the Control Unit/pads/jacket
Additional warranty information can be found at: 
www.speakman.com

WARRANTY

Be sure to wear eye protection.

SAFETY TIPS

IMPORTANT

Product is designed to be used indoors

Product is designed to be used indoors
and outdoors.

and outdoors.

When mounted in outdoor conditions, product must be 

When mounted in outdoor conditions, product must be 
in a covered area and not directly exposed to outdoor 

in a covered area and not directly exposed to outdoor 
elements such as rain and snow.

elements such as rain and snow.

ANSI Z358.1 requires that all self-contained eyewash 
shall be visually inspected weekly, unless the product 
is placed in environments with extreme conditions that 
may affect the form, fit, or function of the unit 
(temperature, dirt, etc.). If this is the case, then the 
inspection should be conducted more often as the end 
user deems necessary. Speakman Company furnishes 
a testing record tag (91-0635) with each unit. On this 
tag, the date of inspection and the inspectors’ initials 
should be noted. ANSI Z358.1 specifies that the 
height of the spray heads is to be between 33” - 45” 
from the floor. The SE-4330 unit weighs approximately 
185 lbs filled. Ensure the mounting surface (wall, etc.) 
and mounting hardware can safely hold a minimum 
vertical load of 300 lbs. Be sure to read instructions 
thoroughly before beginning installation. Do not 
overtighten any connections or damage may occur. 
The unit should be full at all times, to achieve the 
minimum 15 minute run time as stated by ANSI, in 
case of an emergency. Refill the tank to a full level 
after each activation. Before refilling tank dry and 
clean outside of spray heads, and inside of pull strap 
to remove debris, and to assure proper sealing.

MAINTENANCE

Always disconnect power while servicing the unit and 

Always disconnect power while servicing the unit and 
allow the unit to cool down before filling with water.

allow the unit to cool down before filling with water.

Occasional cleaning and disinfection is recommended. 
To clean the inside of the unit, add 1/2 cup (4 fluid 
oz.) of Clorox (liquid bleach) to a full tank of potable 
water. Allow the mixture to penetrate for 15 minutes. 
Drain tank, and rinse thoroughly several times with 
potable water. Take care to not overtighten drain cap 
as damage may occur. For further information about 
Clorox, call toll-free at 1-800-292-2200. Follow 
refilling instructions in this manual and place the tank 
back in service. Should any repair part be required, 
use only genuine SPEAKMAN parts for repair or 
replacement. See available replacement parts in this 
document, to order parts call 1-800-537-2107.

As part routine inspection, the unit shall be checked for 
adequate water level. (Within 5" of the top cap)

WARNING: This units maintains the water
temperature within the tepid range of 60-90 F. 
Depending on the water temperature within the tank 
and the ambient conditions, it may take up to
24 hours for the water temperature to reach the
tepid range during initial start-up. If noted during 
inspection the water temperature is outside that
range, the product should be taken out of service
and the condition troubleshooted.

1

Select a suitable location for the SE-4330. 
When mounted in outdoor conditions, product 

When mounted in outdoor conditions, product 
must be 

must be in a covered area and not directly 

in a covered area and not directly 

exposed to outdoor elements such as rain and 

exposed to outdoor elements such as rain and 
snow.

snow. After confirming the Spray Head height, 
refer to the rough-in diagram for Wall Bracket 
height measurements to determine mounting hole 
locations for the bracket. Making sure the 
bracket is level, mark and drill holes in the 
mounting structure.

Note: 

Mounting hardware not included. Ensure 

the mounting surface (wall, etc.) and mounting 
hardware can safely hold a minimum vertical 
load of 300 lbs.

2

Mount the Wall Bracket using appropriate 
hardware, making sure to torque to 
manufacturer’s specifications, if applicable.

Note: 

Mounting hardware not included. Ensure 

the mounting surface (wall, etc.) and mounting 
hardware can safely hold a minimum vertical 
load of 300 lbs.

3

Install empty Tank to Wall Bracket by first inserting “hook” on the top of the bracket through the 
Jacket Slot located at the upper rear of jacket and into the handle of the Tank (1). Lower the Tank 
inserting the lower bracket section through the Jacket Slot and under the Tank. Push the Tank 
towards the bracket until the Wall Bracket snaps into the recess at the bottom of the Tank (2).

*CROSS SECTION VIEW

HANDLE

WALL
BRACKET

DRAIN

4

CERTIFIED TO ANSI/ISEA Z358.1

Remove the Front Access Panel (1) from
the Jacket (2).

5

Use a flat head screw driver to ensure that the Bracket (1) and the tank's Drain Hole (2) align. The 
Front Access Panel will need to be removed for this process.

* VIEW FROM
UNDER THE TANK

6

Insert Drain Fitting (1) through openings in the Tank and Wall Bracket. From below, reaching 
between the Jacket and the Tank, install Drain Washer (2) and Drain Nut (3) to threaded portion 
of Drain. Wrench tighten. Take care to not over tighten or damage may occur. Retrieve Drain 
Hose (4) from parts accessory bag. Slide threaded Drain Hose (4) through hole in Jacket bottom 
and secure to Drain Fitting (1). Hand tighten only.

* VIEW FROM UNDER THE TANK