INSTALLATION INSTRUCTIONS

CPV-T2-DV-PXC

Thermostatic Shower Valve

with Integral Diverter

92-CPV-T2-PXC-01

CPV-T2-PXC

Thermostatic Shower Valve

800-537-2107

www.speakman.com

NEED HELP?

For additional assistance or service please contact:

TOOLS & SUPPLIES NEEDED

Eye

Protection

IMPORTANT

FINISH MAINTENANCE:

Keep the surface finish looking new by cleaning 
it periodically with a soft cloth. Avoid abrasive 
cleaners, steel wool, and harsh chemicals as 
these will dull the finish and void your warranty.

SAFETY TIPS:

Be sure to read and understand all instructions 

before beginning installation.

Inspect all connections after installation.

Cover the drain to avoid loss of parts.

Be sure to wear proper eye protection.

Do NOT over tighten any connections or damage 

may occur.

Shut OFF water supplies before beginning 

installation.

Observe all local plumbing and building codes.

Risk of personal injury. Do NOT use the Valve 
without properly adjusting the Temperature Limit 
Stop (TLS) as outlined in this installation 
manual.

Ensure proper structure is in place to support 
the Valve and plumbing during use.

VALVE SPECIFICATIONS:

This Valve has an operating range of 20-80 psi.

This Valve is engineered to be used in conjunction 

with a Shower Head rated at 1.35 gpm (5.1 L/min) 

or higher flow rate.

Maximum water pressure: 125 psi static.

Minimum water pressure: 20 psi flowing.

Minimum Cold Supply Temperature: 40°F.

Maximum Hot Supply Temperature: 160°F.

Minimum Hot Supply Temperature: 5°F above set 
point.

CAUTION

MAINTENANCE

Your new product is designed for years of 
trouble-free performance.

This type of valve must be cleaned and 
maintained on a regular basis. Periodic 
maintenance should be performed at least 
every 12 months or after any changes have 
been made to the building’s plumbing system. 
Valves that are installed outdoors should be 
winterized by removing all of the internal parts 
and removing any standing water from the 
valve. Quarterly the maximum hot temperature 
setting (TLS) should be checked and adjusted 
accordingly.

Thread Seal

Tape

Level

Measuring

Tape

Pipe

Wrench

Drill

Pencil

Solder Kit

Flat Tip

Screwdriver

Phillips

Screwdriver

Tubing

Cutter

Mounting

Hardware

(not included)

Phillips

Drive Bit

Slip Joint

Wrench

9/16” (14mm)

Deep Well Socket

Socket

Wrench

Crimp

Ring

PEX

Go/No-Go

Gauge

NO

 GO

GO

NO

 GO

GO

PEX Crimp

Tool

PEX

Cutter

78”

(1981mm)

21”

(533mm)

4”

(102mm)

TO TOP OF

TUB LEDGE

48”

(1219mm)

78”

(1981mm)

TUB/SHOWER

SHOWER ONLY

ROUGH IN VERTICAL REFERENCE

4-½”

114mm

3-½”

89mm

MAXIMUM

FINISHED

WALL

SURFACE

4-3/16”
106mm

MAXIMUM

4-½”

114mm

2-½”

64mm

MINIMUM

FINISHED

WALL

SURFACE

3-3/16”
81mm

MINIMUM

ALIGNS WITH THE

FINISHED WALL AT

THE 

MINIMUM

 ALLOWED

ROUGH IN DEPTH

ALIGNS WITH THE

FINISHED WALL AT

THE 

MAXIMUM 

ALLOWED 

ROUGH IN DEPTH

ROUGH IN DEPTH REFERENCE

Determine the mounting depth of the Valve referencing the diagrams below. The Protective Cover on the 

Valve has reference markings showing where the Valve should align with the Finished Wall Surface. The 

distance from the Finished Wall Surface to the centerline of the Valve 

Outlets MUST

 fall between 

2-1/2” 

Minimum 

and

 3-1/2” Maximum.

Содержание CPV-T2-PXC

Страница 1: ...Hot Supply Temperature 5 F above set point CAUTION MAINTENANCE Your new product is designed for years of trouble free performance This type of valve must be cleaned and maintained on a regular basis P...

Страница 2: ...nents is not necessary If performing a shower only installation ensure the Cap E is properly installed to the lower port of the Valve after applying Thread Seal Tape 4 A PREPARE FOR SOLDERED CONNECTIO...

Страница 3: ...ng Cutters not included to cut the PEX Tubing to length Ensure that a good square 90 cut is obtained A rough or uneven cut will result in a weakened joint PEX CRIMP INSTALLATION INSTRUCTIONS SHOWER HE...

Страница 4: ...2 ROTATE 180 Reverse Installation Standard Installation BACK TO BACK INSTALLATION Your Shower Valve has the ability to be mounted back to back with another Valve in a shared space This means the HOT a...

Страница 5: ...the Valve Spindle counter clockwise The maximum outlet temperature setting adjustment TLS of the Valve has been factory set at 110 F To adjust the limit of the maximum outlet temperature the Valve de...

Страница 6: ...rim from Valve Close the Integral Stops of the Valve by turning the Stop Screws clockwise 2 Remove the Diverter Valve Retaining Nut using a Slip Joint Wrench 3 Remove Diverter Cartridge from the Valve...

Страница 7: ...1 2 NPT MALE CONNECTION 1 2 SWEAT FEMALE CONNECTION 4 48in 0 03 113 8mm 0 8 7 177 8mm 3 1 4 85 5mm COMPLIANCE CONNECTIONS ASME A112 18 1 CSA B125 1 ASSE 1016 ASME A112 1016 CSA B125 16 HOT COLD Inlet...

Отзывы: