background image

 

USER MANUAL 

AM-01/6 

 
 

INDICE

 

Pag. 12 di 14

 

Case of manual control 

 
The AM-01/6-PW system can also be controlled either manually or through a non-SPE 
interface to be connected to the PORT connector. 
 
Typical connection: 
 

 

Use open collector transistors or relay contacts 
where: 
 
Bit = 0  

Transistor ON or closed relay contacts 

Bit = 1  

Transistor OFF or open relay contacts 

 
The antenna selection is made with the following code: 
 
Antenna 

Bit C  Bit B  Bit A 

n.1 

 

n.2 

 

n.3 

 

n.4 

 

n.5 

 

n.6 

 

 
The code is transmitted for as long as the setting remains. 
 
 
 
 
 
 
 

Содержание AM-01/6

Страница 1: ...AM 01 6 Remote Antenna Matrix System USER MANUAL Rev 1 0 ...

Страница 2: ...USER MANUAL AM 01 6 INDICE Pag 2 di 14 Index IMPORTANT 3 UNPACKING 4 EQUIPMENT DESCRIPTION AND USE 5 AM 01 6 SO2R 5 AM 01 6 PW 8 AMB 02 10 CASE OF MANUAL CONTROL 12 WARRANTY TERM 13 ...

Страница 3: ...the Expert 1 3K FA and Expert 1 5K FA the AM 01 6 is able to bring the antennas managed from 4 to 6 IMPORTANT Before installing and using the system we recommend that you carefully read the instructions contained in this manual Failure to comply with these instructions results in voiding the warranty Keep the manual it contains important information regarding the safety and correct use of your AM ...

Страница 4: ...ents If you find any damage or if there are any parts missing contact your distributor dealer immediately Accessories included in the carton AM 01 6 SO2R or AM 01 6 PW as ordered AMB 02 Control Box N 1 PORT connection cable between AMB 02 and Expert amplifiers or Combiner N 1 power cable for AMB 02 ...

Страница 5: ...R Able to manage up to 6 antennas even in the case of Expert 1 3K FA Expert 1 5K FA Maximum power up to 2KW In the case of SO2R operations a two color LED is associated with each antenna connector Red means that the selected antenna is RTX for the band in use Green means that the selected antenna is currently only RX in the other band For a more in depth knowledge of SO2R refer to the amplifier ma...

Страница 6: ...USER MANUAL AM 01 6 INDICE Pag 6 di 14 Typical connection In case of SO2R use press SET then set SO2R MATRIX in the Config menu ...

Страница 7: ...Attention The Matrix was designed for 6 antennas because 6 are contest HF bands This guarantees the passage between band and band with maximum speed If multi band antennas are used WARC and 6m bands can also be set For the 6 m band where a preamplifier and a probable sequencer are often used since a rapid passage with the HF bands is not required it is advisable but not mandatory to have a separat...

Страница 8: ... antenna connector which when lit indicates the selected antenna This Matrix given the high power it can handle has been specifically designed for use in conjunction with our Combiner CO1 2 It can also be used as a simple antenna switch by setting Remote Ant Switch in the Config menu It can also be used with non SPE systems by manually setting the antenna as described later in this manual ...

Страница 9: ...cal connection The figure refers to use as a simple switch in conjunction with the Combiner CO1 2 it is sufficient to replace the amplifier in the figure with the Combiner see its manual on page 17 Press SET then set COMBINER in the Config menu ...

Страница 10: ... the Matrix and therefore the antennas must be connected to the opposite connector There are six LEDs on the panel each representing the condition of the corresponding antenna In the case of AM 01 SO2R Red LED means that the selected antenna is RTX for the band in use Green LED means that the selected antenna is RX only LED off means that the antenna is not selected In the case of AM 01 PW Red LED...

Страница 11: ...s anomalous absorption of 13 8 VDC The PORT connector must be connected via the supplied cable to the corresponding PORT of the Expert amplifier or to the PORT OUT of the Combiner If a longer cable is required build a new one according to the following diagram Note with this cable in the case of the Expert amplifier off the Matrix automatically activates the ANT1 in accordance with the Expert manu...

Страница 12: ...e PORT connector Typical connection Use open collector transistors or relay contacts where Bit 0 Transistor ON or closed relay contacts Bit 1 Transistor OFF or open relay contacts The antenna selection is made with the following code Antenna Bit C Bit B Bit A n 1 0 0 1 n 2 0 1 0 n 3 0 1 1 n 4 1 0 0 n 5 1 0 1 n 6 1 1 0 The code is transmitted for as long as the setting remains ...

Страница 13: ...ompleted with the delivery of the goods to the carrier specified by the Purchaser or failing that to the carrier chosen by SPE The products will travel at the risk of the Purchaser even if at the request of the same one or for other causes SPE should carry out transport or choose the carrier If the original Purchaser finds some defects after having received the equipment he must immediately notify...

Страница 14: ... purchase if any Particular agreements between retailer and Purchaser or particular obligations imposed in other countries are matters for the local retailer and not for SPE In the event of dispute Rome s court of competent jurisdiction will apply By purchasing SPE equipment the Purchaser declares his acceptance of the above Warranty Terms SPE s r l Via di Monteverde 33 00152 Roma Tel 390658209429...

Отзывы: