background image

 

Spartan Power SP-TS4500PLUS 

User Manual 

 

I. Application: 

This power transfer controller allows for trouble-free operation of an inverter and AC 
mains  on the same circuit. The SP-TS4500PLUS  switches automatically between 
inverter power and AC mains while protecting the inverter against external voltage. In 
addition, it offers the possibility to choose the battery power prior between the two 
power sources.   

 

II. Safety Instructions: 

The following safety notes and hazard warnings serve not only for the protection of 
the SP-TS4500PLUS but also for the protection of your health. 
In case of property damage or personal injuries caused by improper handling or 
non-observance of these operating instructions or the safety notes stated herein, the 
warranty will expire. We assume no liability for any consequential damages. 
1.

 

For safety and technical approval reasons, the unauthorized conversion and/or 

modification of the product is not permitted.   
2.

 

This power transfer controller is not a toy and must not be used by children! Please 

ensure childproof operation and storage of the power transfer controller at any time. 
Don’t leave packaging material heedlessly. It could become a hazardous toy for 
children! 
3.

 

Check the power transfer controller and connection cables before starting operation. 

If you detect any damages (e.g. transport damages) on the power transfer controller, 
do not start operation. Damaged connection cables must be replaced immediately. 
4.

 

The power transfer controller may only be operated in a dry environment to avoid 

getting humid or wet, otherwise there is a risk of life-threatening electrical shocks. 
5. The use of the product under unfavorable environmental conditions must be 
avoided under all circumstances. 
Unfavorable environmental conditions include: ambient temperatures above 50

flammable gases, solvents, vapors, dust, relative humidity in excess of 80%, and 
moisture. 
6. Do not use the switching station near ignition sources, open fire or other heat 
sources (heating, gas stoves or strong solar radiation).   
7. Service and repairs may only be carried out by authorized and qualified personnel. 
Use only original spare parts for repair work. The use of any other spare parts may 
lead to serious damage to property and personal injury! 
 

III. Product Introduction: 

This dual power transfer controller is used between an off-grid system and public 
power. The controller is separately connected with public power, inverter, battery and 
load.  On the top of the controller, there is an on/off switch, please turn on the 
controller after ensuring all cables are well connected.   

Содержание SP-TS4500PLUS

Страница 1: ...oy for children 3 Check the power transfer controller and connection cables before starting operation If you detect any damages e g transport damages on the power transfer controller do not start operation Damaged connection cables must be replaced immediately 4 The power transfer controller may only be operated in a dry environment to avoid getting humid or wet otherwise there is a risk of life t...

Страница 2: ...ing the switching voltage function 2 BAT V interface normal displaying battery voltage 3 HV SW interface setting the recovery voltage 4 12V 24V 48V interface displaying after the system identification 5 LCD digital a Battery voltage b Low voltage setting switching voltage ...

Страница 3: ...ds to save the value Then the interface will restore to BAT V interface f When function setting display HV SW interface LCD digital displays low voltage recovery voltage default value You can press the add minus buttons to modify the default value Press and hold the function button for 3 seconds to save the value Then the interface will restore to BAT V interface g LCD backlight Without a pressed ...

Страница 4: ...controller for three phase current 9 After ensuring all the steps above connect the controller separately with public power inverter load and battery 10 Turn on the switch after all the cables are well connected Attention 1 The dual power transfer controller is simply a switch between off grid power system and public power it can t replace the charge controller in the off grid system Connection Ty...

Страница 5: ...tching voltage and the switching action is LCD The right arrow blinks the LCD Left arrow turns off and the battery icon blinks b When it is detected that the battery voltage recovers to 25V for 2 seconds system default value is 25V it is the low voltage recovery voltage and the switching action is LCD The right arrow turns off the LCD Left arrow blinks and the battery icon stops blink 48V System 1...

Страница 6: ...ecovery Default 13 5V 27V 54V Application Off grid Solar or Wind System Product Size 7 4 X 6 7 X 2 8 Weight VIII Environmental Protection Notes At the end of its useful life this product must not be disposed of together with normal household waste but has to be dropped off at a collection center for the recycling of electrical and devices The materials of this product are recyclable With recycling...

Страница 7: ...the following conditions we need to charge even if it is in the guarantee period User did not operate according to the user s manual Use the product under conditions which is beyond using standard and technical requirements Repaired by yourself or reformed by yourself Used during inappropriate environmental condition which can cause breakdown and aging of the product Improper carrying or storage F...

Отзывы: