Spark modern fires SS-36N Скачать руководство пользователя страница 1

If you smell gas:

1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from 
    the appliance and immediately call
    your gas supplier or fire department.

DANGER

OWNER’S OPERATION AND INSTALLATION MANUAL

We recommend that our products be installed

and serviced by professionals who are certified
in the U.S. by NFI (National Fireplace Institute).

Complies with

WARNING

WARNING

DANGER

CARBON MONOXIDE

         HAZARD

WARNING:

 

For Outdoor Use Only

Report # 

401-O-06-5

STAINLESS STEEL 

O

UTDOOR FIREPLACE

with electronic ignition system

 

              

             Models: SS-36(N,P), SS-48(N,P)

INSTALLER: Leave this manual with the appliance. 

CONSUMER: Retain this manual for future reference.

2.  

An  LP-cylinder  not  connected  for 

use shall not be stored in the vicinity of
 this or any other aplliance.

1. 

Do not store or use gasoline or other

flammable  vapors  and  liquids  in  the
vicinity of this or any other aplliance.

Improper  installation,  adjustment,  alteration,
service  or  maintenance  can  cause  injury  or
property  damage.  Read  the  instalation,  ope-
rating and maintenance instructions thoroughly
before installing or servicing this equipment.

This  appliance  can  produce
carbon monoxide which

 

has

 

no  odor.  Using  it  in  an

enclosed space can kill you.
Never  use  this  appliance  in
an  enclosed  space  as  a 
camper, tent, car or home

ANS

I

 Z21.97 - 

CSA 

2.41-2012

 

"

Outdoor 

Decorative 

Gas 

Appliances"

,

CGA 

2.17-M91(R2009) "Gas Fired Appliances for Use at High Altitudes"

SPARK MODERN FIRES

Содержание SS-36N

Страница 1: ... CONSUMER Retain this manual for future reference 2 An LP cylinder not connected for use shall not be stored in the vicinity of thisor any other aplliance 1 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other aplliance Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the instalation ope r...

Страница 2: ...iring 18 Gas Connection 19 Checking Gas Pressure 20 Placing Glass Panel and Media Tray 22 Lighting Instructions 23 Operating Instructions 24 To Turn Off Gas to Appliance 25 Inspecting Burners 26 Cleaning and Maintenance 27 Troubleshooting 28 Proflame Control Wiring Diagram 32 Illustrated Parts Breakdown 33 Warranty Information Back Cover ...

Страница 3: ... Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchanger insertorotheraccessorynotap proved for use with this heater WARNING Do not allow fans toblowdirectlyintothefireplace Avoidanydraftsthatalterb...

Страница 4: ...under dusty conditions 10 Do not use this fireplace to cook food or burn paper or other objects SAFETY INFORMATION Continued 11 Do not use fireplace if any part has been exposed to or under water Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water 12 Turn fireplace off and let cool before ...

Страница 5: ...tion Electronic Pressure Manifold 10 0 ModeP Maximum 13 0 Minimum 11 0 W C Inlet Gas Pressure in of water W C Inlet Gas Pressure in of water Model SS 48N Btu Variable 60 000 Type Gas Natural Gas Ignition Electronic Pressure Manifold 3 5 Orifice 21 Shipping Weight 155 Lbs Model SS 48P Btu Variable 56 000 Orifice 41 Shipping Weight 155 Lbs Maximum 10 5 Minimum 5 0 ...

Страница 6: ... BOTH SIDES 36 18 29 75 17 31 8 15 Model SS 36P SS 36 FIREPLACE SPECIFICATIONS Orifice 49 Shipping Weight 135 Lbs Btu Variable 38 000 ModeP Shipping Weight 135 Lbs Model SS 36N W C Inlet Gas Pressure in of water W C Inlet Gas Pressure in of water Btu Variable 40 000 Type Gas Natural Gas Ignition Electronic Pressure Manifold 3 5 Maximum 10 5 Minimum 5 0 Orifice 34 6 ...

Страница 7: ...T National Pipe Thread inlet connection to the pressure regulator WARNING Aqualifiedservice person must connect fireplace to gas supply Follow all local codes CAUTION Neverconnectpro pane LP fireplace directly to the propane LPsupply Thisfireplace requires an external regulator notsupplied Installtheexternal regulator between the fireplace and propane LP supply IMPORTANT Allow for a mini mum space of 1...

Страница 8: ...ut any enclosure in which the appliance is used shall comply with one of the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that includes an overhead cover and more than two walls the following shall apply At least 25 of the total wall area is completely open and At least 30 of the remaining wall ar...

Страница 9: ...ble material other than wood flooring If installed on carpet or vinyl flooring the appliance shall be installed on a metal wood or noncombustible material panel extending full width and depth of the appliance WARNING The fireplace face may be completely covered with any non combustible ma 6 6 6 6 6 6 12 maximum depth COMBUSTIBLE MANTEL Combustibles Clearance to INSTALLATION 9 12 minimum Minimum 16...

Страница 10: ...ENSIONS MINIMUM NON COMBUSTIBLE MATERIAL AREA E S U N I S B A T G N I N E T S A F COMBUSTIBLE MATERIAL NON COMBUSTIBLE MATERIAL AREA INSTALLATION Continued PLEASE NOTE Framing may need to be recessed from 3 4 to 1 1 2 depending on layers and type of facing material used during installation 30 0 5 61 0 625 min 30 min 61 10 ...

Страница 11: ...MATERIAL FACING WITH ONE LAYER THREE WAYS TO ALLOW AIR FLOW TO FRONT AIR VENT min 61 min 30 NON COMBUSTIBLE MATERIAL minimum61 wide X 30 high LEAVE MINIMUM 1 2 X 26 SLOT CLEAR FOR THE LOUVER AREA ON BOTH FACES MODEL SS 48 INSTALLATION Continued Figure 1 1 Installation of facing materials Case 1 11 ...

Страница 12: ...OMBUSTIBLE MATERIAL ALLOW FOR MINIMUM 13 SQUARE INCHES OF AIR FLOW ALLOW FOR MINIMUM 13 SQUARE INCHES OF AIR FLOW min 30 min 61 min 61 min 30 COVER WITH SECOND LAYER OF FACE MATERIAL SECOND LAYER LEAVE THE LOUVER AREA CLEAR WITH FIRST LAYER OF FACE MATERIAL FIRST LAYER minimum 61 wide X 30 high MODEL SS 48 INSTALLATION Continued Figure 1 2 Installation of facing materials Case 2 12 ...

Страница 13: ...MBUSTIBLE MODEL SS 48 INSTALLATION Continued Figure 1 3 Installation of facing materials Case 3 VIEW FROM BACK OF SURROUND FACING MATERIAL ALLOWING AIR FLOW FROM BEHIND SURROUND 13 Leave the louver area clear allow for minimum 13 sq inches of air flow Leave the louver area clear allow for minimum 13 sq inches of air flow ...

Страница 14: ... 0 50 49 49 48 48 49 0 625 COMBUSTIBLE MATERIAL NON COMBUSTIBLE MATERIAL AREA 34 49 MODEL SS 36 INSTALLATION Continued PLEASE NOTE Framing may need to be recessed from 3 4 to 1 1 2 depending on layers and type of facing material used during installation FACING DIMENSIONS MINIMUM NON COMBUSTIBLE MATERIAL AREA 14 ...

Страница 15: ...LE MATERIAL min 49 min 30 NON COMBUSTIBLE MATERIAL minimum 49 wide X 34 high FACING WITH ONE LAYER THREE WAYS TO ALLOW AIR FLOW TO FRONT AIR VENT LEAVE MINIMUM 1 2 X 26 SLOT CLEAR FOR THE LOUVER AREA MODEL SS 36 INSTALLATION Continued Figure 2 1 Installation of facing materials Case 1 min 34 15 ...

Страница 16: ...COMBUSTIBLE MARBLE STONE OPTION 2 NON COMBUSTIBLE MATERIAL NON COMBUSTIBLE MATERIAL FACING WITH TWO LAYERS MATERIALS IE DUROCK CEMENT BOARD GRANITE min 49 min 49 min 34 minimum 49 wide X 34 high min 34 ALLOW FOR MINIMUM 13 SQUARE INCHES OF AIR FLOW ALLOW FOR MINIMUM 13 SQUARE INCHES OF AIR FLOW MODEL SS 36 INSTALLATION Continued Figure 2 2 Installation of facing materials Case 2 16 ...

Страница 17: ...INSTALLATION Continued Figure 2 3 Installation of facing materials Case 3 FACING WITH THICK LAYER OF NON COMBUSTIBLE MATERIAL ALLOWING AIR FLOW FROM BEHIND SURROUND ALLOW MINIMUM 13 SQUARE INCHES OF AIR FLOW 17 Leave the louver area clear allow for minimum 13 sq inches of air flow View from back of surround ...

Страница 18: ...ition and Canadian Electrical Code CSA C22 1 INSTALLATION Continued This fireplace requires 110V AC electrical supply for normal operation in order to power up supplied 7V AC DC adapter which is required to operate Remote Control However during power outage situation its electronic system DFC board can be temporary powered with 9V DC batery and main valve can be operated manually using ON OFF posi...

Страница 19: ...Pipe Tee Nipple Joint Natural Gas From Gas Meter 5 W C to 10 5 W C Pressure Propane LP From External Regulator 11 W C to 14 W C Pressure CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace If pipe is too small undue loss of volume will occur Inst...

Страница 20: ... the appliance s rating decal If the gas supply is different from the fireplace STOP Do not install the appliance Contact your dealer immediately 2 To ease installation a 30 mm flex line with manual shut off valve has been provided with on this appliance Install and attach 1 2 gas line onto shut off valve Outlet Pressure Tap Pilot Adjustment Inlet Pressure Tap 4 Do not use open flame to check for ...

Страница 21: ...ming show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equipment shutoff valve to gas supply Check reconnected fittings for leaks INSTALLATION Continued Open Closed Equipment Shutoff Valve 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 ...

Страница 22: ...ay completely with the supplied clear glass media 22 2 Locate the glass wind shield panel and slide down into the support brackets Assure the panel is centered in the fireplace and the support brackets are fastened securely 3 Fill the tray with media supplied Do not place media on burner or block air flow between burner and tray 4 Your fireplace is ready for operation ...

Страница 23: ...ualified service technician if you have any safety concerns D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water LIGHTING INSTRUCTION FOR YOUR SAFETY READ BEFORE OPERATING LIGHTING FOR THE FIRST TIME INITIAL LIGHTING Purg...

Страница 24: ... pilot by hand If you don t smell gas go to the next step WARNING 7 Turn the gas control manual valve to the ON position 8 Plug supplied 7V DC adapter into 110V power outlet LIGHTING FOR THE FIRST TIME 5 Turn the gas control manual valve to the full OFF position 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety infor...

Страница 25: ... outlet 3 Turn the gas control manual valve to the full OFF position 1 Turn off all electric power to the appliance if service is to be performed 2 If necessary remove Media Tray from the appliance to access manual shutoff valve on gas line 4 If necessary replace Media Tray 25 ...

Страница 26: ...will have a slight curve but flame should be blue and have no yellow or orange color If pilot flame pattern is incorrect Figure 7 Correct Pilot Flame Pattern Figure 7 shows a correct pilot flame Figure 8 shows correct burner flame pattern withpatern with yellow flame tips and blue base Figure 9 shows incorrect flame pattern The incorrectburner flame pattern shows lazy orange flame If burner fl ame patt...

Страница 27: ...y compressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the directions on the can If you donʼt follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes Figure 10 Air Mixer Injector On Burner Tube LP models only Clean the pilot assemb...

Страница 28: ...e if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Call for service 5 Replace pilot assembly 6 Replace pilot assembly gas company Cleaning and Maintenance 5 Replace gas control 1 Reconnect ignitor cable 1 Gas supply turned off or equipment shutoff valve 1 Turn on gas supply or open equipment shutoff valve When remote button is pressed there is spark at pilot but n...

Страница 29: ...essure is too 1 Contact local natural or pilot is lit low propanc LP gas company or replace burner orifice 3 Burners will not come on 3 Replace battery in transmit in remote position ter and receiver Delayed ignition of burner 1 Manifold pressure is too 1 Contact local natural or low propane LP gas company 29 2 Burner orifice clogged 2 Clean burner see Cleaning and Maintenance page 27 or replace b...

Страница 30: ...r Combustion ticed on windows ventilation air and Vcntilation require 1 Air in gas line 1 Operate burners until air is removed from line Have White powder residue form 1 When heated vapors from 1 Turn heater off when using ing within burner box or on furniture polish wax car furniture polish wax clean adjacent walls or furniture pet cleaners etc turn into ers or similar products Remote does not fu...

Страница 31: ... burners are lit or shut off Fireplace produces unwanted odors Gas odor even when control knob is in OFF position 1 Fireplace burning vapors 1 Open window and ventilate from paint hair spray room Stop using odor cans glues cleaners chemicals ing products while fireplace new carpet etc see is funning IMPORTANT statement above 1 Metal expanding while 1 This is common with heating or contracting most...

Страница 32: ...Proflame Wiring Diagram 17 18 4 5 Optional 6 Volt Battery Backup 18 16 17 13 15 This diagram shows replaceable SIT Proflame parts used in your fireplace please refer to pages 34 35 32 ...

Страница 33: ...ILLUSTRATED PARTS BREAKDOWN 1 2 8 9 10 11 5 4 3 3 17 17 7 12 13 6 19 16 33 ...

Страница 34: ... 8 NPS X 3 8 FLARE 90 DEG FITTING 1 10 C100009 C100009 3 8 X 24 FLEX CONNECTOR 1 11 F200066 F200066 SUPPLIED SHUTOFF VALVE 1 12 W800006 SS W800006 SS MEDIA TRAY 1 13 H200012 H200012 WIRE HARNESS 1 14 C100020 C100020 DUPLEX POWER OUTLET not shown 1 15 PCB PCB SKYTECH REMOTE CONTROL 1 16 PCB R PCB R SKYTECH REMOTE RECEIVER 1 17 H100140 H100140 7V AC DC POWER ADAPTER 1 18 H100142 H100142 S I T DFC CO...

Страница 35: ... 8 NPS X 3 8 FLARE 90 DEG FITTING 1 10 C100009 C100009 3 8 X 24 FLEX CONNECTOR 1 11 F200066 F200066 SUPPLIED SHUTOFF VALVE 1 12 W800008 SS W800008 SS MEDIA TRAY 1 13 H200012 H200012 WIRE HARNESS 1 14 C100020 C100020 DUPLEX POWER OUTLET not shown 1 15 PCB PCB SKYTECH REMOTE CONTROL 1 16 PCB R PCB R SKYTECH REMOTE RECEIVER 1 17 H100140 H100140 7V AC DC POWER ADAPTER 1 18 H100142 H100142 S I T DFC CO...

Страница 36: ...Manufactured by Woodbridge Fireplace Inc 18AStrathearn Ave Units 25 27 Brampton Ontario Canada L6T4X7 REV 1 09 2013 ...