WARNING: If the information in this manual 

is not followed exactly, a fire or explosion 

may  result  causing  property  damage,  

personal injury, or loss of life.
—  Do not store or use gasoline or other 

 flammable  vapors  and  liquids  in  the 

 vicinity of this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do

not use any phone in your building.

• Immediately  call  your  gas  supplier

from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

—  Installation  and  service  must  be  

performed  by  a  qualified  installer,  

service agency, or the gas supplier.

This is an unvented gas-fired heater. It uses 

air (oxygen) from the room in which it is 

installed. Provisions for adequate combus-

tion and ventilating air must be provided. 

Refer  to  page  4, 

Air  for  Combustion  and 

Ventilation. 

This  appliance  may  be  installed  in  an 

aftermarket,*  permanently  located,  manu-

factured (mobile) home, where not prohib-

ited by local codes.
This appliance is only for use with the type 

of  gas  indicated  on  the  rating  plate. This  

appliance  is  not  convertible  for  use  with 

other gases. 

WARNING:  Improper  installation,  adjust-

ment,  alteration,  service,  or  maintenance 

can cause injury or property damage. Refer 

to this manual for correct installation and 

operational procedures. For assistance or 

additional information consult a qualified in-

staller, service agency, or the gas supplier.

T

his heater shall not be installed in a room

or space unless the required volume of the

indoor combustion air is provided by the 

method described in the National Fuel Gas

Code, ANSI Z223.1/NFPA 54, the Internatio-

nal Fuel Gas Code, or applicable local codes 

* Aftermarket: Completion of sale, not for purpose of resale, from 
the manufacturer

UNVENTED (VENT-FREE) 

SEE THRU 

GAS FIREPLACE 

      

WITH ELECTRONIC IGNITION SYSTEM

     

MODELS: 5

9

(N,P)

INSTALLER: Leave this manual with the appliance. 

CONSUMER: Retain this manual for future reference

Version française de ce manuel est disponible à partir du site WEB : www.sparkfires.com

Содержание 59N

Страница 1: ...This appliance may be installed in an aftermarket permanently located manu factured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on t...

Страница 2: ...liance be kept clean 7 2 217 176 Safety Information 3 Local Codes Specifications 4 Locating Firebox 5 Product Specifications 5 Air For Combustion and Ventilation 6 Installation 8 Framing 10 Operating...

Страница 3: ...be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change...

Страница 4: ...er dusty conditions 10 Do not use this replace to cook food or burn paper or other objects SAFETY INFORMATION Continued 11 Do not use fireplace if any part has been exposed to or under water Immediate...

Страница 5: ...ombustion and ventilation PRODUCT SPECIFICATIONS RIGHT SIDE VIEW 60 48 28 75 8 15 25 75 28 75 FRONT VIEW TOP VIEW GAS LINE ACCESS BOTH SIDES 25 75 13 75 18 Maximum 10 5 Minimum 5 0 Ignition Electronic...

Страница 6: ...gs of unusually tight construction you must provide additional fresh air Unusually tight construction is de ned as construction where a walls and ceilings exposed to the out side atmosphere have a con...

Страница 7: ...vent gas appliances Di rect vent draws combustion air from the outdoors and vents to the outdoors Example Gas water heater __________ Btu Hr Vent free replace ________ Btu Hr Total ________ Btu Hr 4...

Страница 8: ...ts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Figure 2 Ventilation...

Страница 9: ...n page 6 IMPORTANT Make sure the replace is level If replace is not level it will not work properly CHECK GAS TYPE Use the correct gas type natural or propane LP for your replace If your gas supply is...

Страница 10: ...an external regulator notsupplied Installtheexternal regulator between the replace and propane LP supply VENT FREE FIRE RIBBON FRAMING DIMENSIONS 26 61 E S U N I S B A T G N I N E T S A F 0 625 29 0 5...

Страница 11: ...LEAVE MINIMUM 1 2 X 26 SLOT CLEAR FOR THE LOUVER AREA ON BOTH FACES Figure 4 1 Installation of facing materials Case 1 IE DUROCK CEMENT BOARD GRANITE MARBLE STONE OF NON COMBUSTIBLE MATERIAL OPTION 1...

Страница 12: ...6 Figure 4 2 Installation of facing materials Case 2 COVER WITH SECOND LAYER OF FACE MATERIAL SECOND LAYER LEAVE THE LOUVER AREA CLEAR WITH FIRST LAYER OF FACE MATERIAL FIRST LAYER SIDE VIEW ALLOW AIR...

Страница 13: ...COMBUSTIBLE FACING MATERIAL ALLOWING AIR FLOW FROM BEHIND SURROUND VIEW FROM BACK OF SURROUND NOTCH OUT BACK OF FACE MATERIAL TO ALLOW MINIMUM 13 SQUARE INCHES OF AIR FLOW ALLOW AIRFLOW NON COMBUSTIB...

Страница 14: ...7V AC DC adapter which is required to operate Remote Control However during power outage situation its electronic system DFC board can be temporary powered with 9V DC batery and main valve can be oper...

Страница 15: ...quipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from replace IMPORTANT Install equipment shutoff valve in an accessible...

Страница 16: ...equipment shutoff valve to fireplace Route flexible gas supply line through one of the access holes 3 Attach the flexible gas line to gas supply as per Figure 7 Check tightness of flexible gas line a...

Страница 17: ...5 Correct all leaks at once 6 Reconnect replace and equipment shutoff valve to gas supply Check reconnected ttings for leaks INSTALLATION Continued Figure 8 Equipment Shutoff Valve Open Closed Equipm...

Страница 18: ...ION 1 Locate optional media tray OPTIONAL MEDIA TRAY PLACEMENT 2 Place media tray on the support brackets as shown 3 Fill the tray with media supplied Do not place media on burner or block air flow be...

Страница 19: ...applying any power supply to the DFC board please verify that the electrical connections illustrated parts list or mounted in adjacent wall Make sure that the remote receiver switch is in REMOTE midd...

Страница 20: ...s into the receiver batter bay Note the polarity of the batteries and insert into the battery bay as indicated on the battery covel 2 Place the 3 posilion slider switch in the REMOTE position 3 Insert...

Страница 21: ...the room thermostat is ON and the set temperature is now displayed see Figure 14 2 Adjust the set temperature by pressing the up or down arrow keys until the desired set temperature is displayed on th...

Страница 22: ...are low no beep will sound from the receiver when a transmitter command is sent Replace batteries when this happens Transmitter The life span of the transmitter batteries depends upon various factors...

Страница 23: ...shows a correct pilot ame pilot ame pattern pattern Figure 18 shows an incorrect Figure 17 Correct Pilot Flame Pattern Figure 18 Inorrect Pilot Flame Pattern If pilot ame pattern is incorrect as show...

Страница 24: ...um cleaner in the blow position If using com pressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the u...

Страница 25: ...5 Gas regulator setting is not correct 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Call for service 5 Replace pilot assembly 6 Replace pilo...

Страница 26: ...e Cleaning and Maintenance caused by one or both of page 24 or replace ODSI 3 Flame sensor connection 3 Hand tighten until snug loose at control valve then tighten 1 4 turn more 2 Burner orifice clogg...

Страница 27: ...n burner see Cleaning and Maintenance page 24 Moisture condensation no 1 Not enough combustion I Refer to Airfor Combustion ticed on windows ventilation air and Vcntilation require Heater produces a w...

Страница 28: ...and Maintenance 1 Foreign matter between 1 Take apart gas tubing and control valve and burner remove foreign matter Fireplace produces a clicking ticking noise just after burners are lit or shut off F...

Страница 29: ...NPUT 7 Volt DC STABILIZED SUPPLY OUTPUT MOTOR RECEIVER DC SUPPLY SPLIT FLOW ON OFF TPTH TH DFC SUPPLY DC SUPPLY GROUND 885 PROFLAME Orange Green 11 29 17 18 4 20 19 16 21 This diagram shows replaceabl...

Страница 30: ...ILLUSTRATED PARTS BREAKDOWN 1 2 3 4 5 6 7 8 9 10 30 1 9 1 7 2 0 21 4 1 22 11 13 for references see page 31...

Страница 31: ...CTOR 1 This list contains replaceable parts used in your rebox All replacement parts should be ordered from your installer or from Spark Modern Fires at 1 8669 383 846 or on line at www sparkfires com...

Страница 32: ...reinstallation or transportation of defective parts on the appliance or 3 indentical or consequential damage All service work must be performed by an authorized service representative This warranty i...