DISPLAY MODES
The XS-2000 topside panel features a large LCD
screen which displays three items: (1) Actual Water
Temperature (2) Set Temperature Point (3) Time &
Day. By default the set temperature point is displayed
in the large digits (refer below).
There are three possible items that can be displayed
in the large digits: (1) Actual Water Temperature
[W.TMP]; (2) Set Temperature [S.TMP]*; (3) Time
Clock [TIME]. Each display mode has a unique icon
shown at the top of the screen to indicate the current
item being viewed (refer below).
Press the
UP
( ) or
DOWN
( ) button to scroll
through these different display modes. As you scroll
through each item a brief title screen will be shown
followed by the actual display mode (note change in
icon).
Note: There is a ten (10) second timeout on viewing non
default display modes. If no button press is sensed after 10
seconds the screen will return to the default display.
LED INDICATOR LIGHTS
The AUTO LED indicator turns ON when
the filtration pump is in automatic mode.
The Heater LED indicator turns ON when
the heater element is active.
The Ozone LED indicator turns ON when
the ozonator / UV sanitiser is active.
The Sleep Cycle LED indicator turns ON when
in a designated sleep cycle (if programmed).
ADJUST SET TEMPERATURE POINT
The SpaNET intelligent software constantly monitors
the spa water, automatically controlling the heater
and circulation pump to ensure the desired set water
temperature is maintained. The user can adjust the
o
o
set temperature point from 5 C - 41 C in steps of
o
o
0.2 C increments (Default: 38 C).
To adjust the set temperature point:
1)
Press and hold
the
UP
( ) or
DOWN
( )
button. The set temperature point will begin
o
adjusting up or down in 0.2 C increments.
2) Once the desired set temperature is displayed
press the
OK
( ) button to confirm selection.
Notes: 1) f the standard in-heater temperature sensor is
used (i.e. no optional in-pool temperature sensor fitted) the
o
heater works off a 2 C hysteresis (thermostat). The heater
will raise the water to the set temperature point but
thereafter will not be re-activated until the water
o
temperature falls by at least 2 C.Therefore if the spa user
o
selects a set temperature point of 38 C the actual water
o
o
temperature will be anywhere between 36 C - 38 C
depending on when the user checks the temperature.
2) If the optional in-pool temperature sensor is fitted the
o
heater works off a 0.5 C hysteresis (thermostat). The
heater will raise the water to the set temperature point but
thereafter will not be re-activated until the water
o
temperature falls by at least 0.5 C. Therefore if the spa
o
user selects a set temperature point of 38 C the actual
o
o
water temperature will be anywhere between 37.5 C - 38 C
depending on when the user checks the temperature.
CLOCK
For convenient user reference and to assist in
filtration & sleep time functions, your spa controller
includes a built-in real time clock. The user can
choose to display the time in either 12 or 24 hour
format. For ease of reference the current time and
day is displayed at the bottom left of the LCD
screen.
To set the clock:
1) Press the
UP
( ) or
DOWN
( ) button to
toggle the screen to the
TIME
( ) display
mode.
2) Press the
OK
( ) button to enter set time
adjustment.
3) Press the
UP
( ) or
DOWN
( ) button to
select the time format (12 or 24 HR). Press
the
OK
( ) button to confirm selection.
4) Press the
UP
( ) or
DOWN
( ) button to
modify the weekday (Mon - Sun). Press the
OK
( ) button to confirm selection.
5) Press the
UP
( ) or
DOWN
( ) button to
modify the hour. Press the
OK
( ) button to
confirm selection.
6) Press the
UP
( ) or
DOWN
( ) button to
modify the minutes. Press the
OK
( ) button
to confirm selection.
WATER TEMP / TIME TOGGLE BUTTON
By default the XS-2000 will display the set
temperature point on the screen. The water temp /
time toggle button is a shortcut key designed to
quickly switch between the actual water temperature
[W.TMP] and the time clock [TIME] display modes.
Press the
W.TMP / TIME
( ) button to toggle
the screen between the actual water temperature
and time clock display modes (refer below).
XS-2000 Quick Reference Guide
OK
Buttons:
1.
UP
2.
3.
4.
Water Temp / Time
5.
6.
7.
8.
Air Blower
9.
Light
(On /Off)
Indicator Lights
10.
Auto Mode LED
11.
Element On LED
12.
Ozone/UV On LED
13.
Sleep Cycle LED
One-Touch Sanitise
OK
DOWN
Pump A
Pump B
AUTO
3
O
zZz
W.TMP Water Temperature
S.TMP Set Temperature*
TIME
Clock
* Default Display
OK
OK
OK
OK
OK
Safety Notes:
The appliance must be connected to a suitably rated and
weather protected power supply. The supply line should be a
dedicated power circuit and means for disconnection must
be incorporated in the fixed wiring in accordance with your
local wiring regulations.
Means for disconnection from the
supply mains should have a contact separation in all poles
that provide full disconnection under overvoltage category III
conditions.
The appliance must be supplied through a
residual current device (RCD) having a rated residual
operating current not exceeding 30mA.
This appliance is
not intended for use by young children or infirm persons
without supervision.
AM
PM
OFF
ON
°C
°F
MODE
SPD
BRT
SAT SUN MON TUE WED THU FRI
38.00
S.TMP Display Mode Icon
Set Water Temperature
W.TMP Display Mode
TIME Display Mode
AM
PM
OFF
ON
°C
°F
MODE
SPD
BRT
SAT SUN MON TUE WED THU FRI
37.60
AM
OFF
ON
MODE
SPD
BRT
SAT SUN
TUE WED THU FRI
MON
:
1000
SV-2T
1
3
4
9
8
5
6
7
10
11
12
13
2