background image

DISPLAY MODES

The XS-2000 topside panel features a large LCD 
screen which displays three items: (1) Actual Water 
Temperature (2) Set Temperature Point (3) Time & 
Day. By default the set temperature point is displayed 
in the large digits (refer below). 

There are three possible items that can be displayed 
in the large digits: (1) Actual Water Temperature 
[W.TMP]; (2) Set Temperature [S.TMP]*; (3) Time 
Clock [TIME]. Each display mode has a unique icon 
shown at the top of the screen to indicate the current 
item being viewed (refer below). 

Press the 

UP 

(       ) or 

DOWN

 (       ) button to scroll 

through these different display modes.  As you scroll 
through each item a brief title screen will be shown 
followed by the actual display mode (note change in 
icon).

Note: There is a ten (10) second timeout on viewing non 
default display modes. If no button press is sensed after 10 
seconds the screen will return to the default display. 

LED INDICATOR LIGHTS

The AUTO LED indicator turns ON when 
the filtration pump is in automatic mode.

The Heater LED indicator turns ON when 
the heater element is active.

The Ozone LED indicator turns ON when 
the ozonator / UV sanitiser is active.

The Sleep Cycle LED indicator turns ON when 
in a designated sleep cycle (if programmed). 

ADJUST SET TEMPERATURE POINT

The SpaNET intelligent software constantly monitors 
the spa water, automatically controlling the heater 
and circulation pump to ensure the desired set water 
temperature is maintained. The user can adjust the 

o

o

set temperature point from 5 C - 41 C  in steps of 

o

 

o

0.2 C increments (Default: 38 C).

To adjust the set temperature point:

1)

Press and hold

 the 

UP 

(       ) or 

DOWN

 (       ) 

button. The set temperature point will begin 

o

adjusting up or down in 0.2 C increments. 

2) Once the desired set temperature is displayed 

press the 

OK

 (       ) button to confirm selection.

Notes: 1) f the standard in-heater temperature sensor is 
used (i.e. no optional in-pool temperature sensor fitted) the 

o

heater works off a 2 C hysteresis (thermostat). The heater 
will raise the water to the set temperature point but 
thereafter will not be re-activated until the water 

o

temperature falls by at least 2 C.Therefore if the spa user 

o

selects a set temperature point of 38 C the actual water 

o

o

temperature will be anywhere between 36 C - 38 C 
depending on when the user checks the temperature.

2) If the optional in-pool temperature sensor is fitted the 

o

heater works off a 0.5 C hysteresis (thermostat). The 
heater will raise the water to the set temperature point but 
thereafter will not be re-activated until the water 

o

temperature falls by at least 0.5 C. Therefore if the spa 

o

user selects a set temperature point of 38 C the actual 

o

o

water temperature will be anywhere between 37.5 C - 38 C 
depending on when the user checks the temperature.

CLOCK

For convenient user reference and to assist in 
filtration & sleep time functions, your spa controller 
includes a built-in real time clock. The user can 
choose to display the time in either 12 or 24 hour 
format. For ease of reference the current time and 
day is displayed at the bottom left of the LCD 
screen.

To set the clock:

1) Press the 

UP

 (       ) or 

DOWN

 (       ) button to 

toggle the screen to the 

TIME

 (      ) display 

mode.

2) Press the 

OK

 (       ) button to enter set time 

adjustment.

3) Press the 

UP

 (       ) or 

DOWN

 (       ) button to 

select the time format (12 or 24 HR). Press
the 

OK

 (       ) button to confirm selection. 

4) Press the 

UP

 (       ) or 

DOWN

 (       ) button to 

modify the weekday (Mon - Sun). Press the

OK

 (       ) button to confirm selection.

5) Press the 

UP

 (       ) or 

DOWN

 (       ) button to 

modify the hour. Press the 

OK

 (       ) button to 

confirm selection.

6) Press the 

UP

 (       ) or 

DOWN

 (       ) button to 

modify the minutes. Press the 

OK

 (       ) button

to confirm selection.

WATER TEMP / TIME TOGGLE BUTTON

By default the XS-2000 will display the set 
temperature point on the screen. The water temp / 
time toggle button is a shortcut key designed to 
quickly switch between the actual water temperature 
[W.TMP] and the time clock [TIME] display modes. 
Press the 

W.TMP / TIME

 (          ) button to toggle 

the screen between the actual water temperature 
and time clock display modes (refer below). 

XS-2000 Quick Reference Guide

OK

Buttons:

1.

UP

2.
3.
4.

Water Temp / Time

5.
6.
7.
8.

Air Blower

9.

Light

 

(On /Off)

Indicator Lights

10.

Auto Mode LED

11.

Element On LED

12.

Ozone/UV On LED

13.

Sleep Cycle LED

One-Touch Sanitise
OK

DOWN
Pump A
Pump B

AUTO

3

O

zZz

W.TMP Water Temperature

S.TMP Set Temperature*

TIME

Clock

* Default Display

OK

OK

OK

OK

OK

Safety Notes: 

The appliance must be connected to a suitably rated and 
weather protected power supply. The supply line should be a 
dedicated power circuit and means for disconnection must 
be incorporated in the fixed wiring in accordance with your 
local wiring regulations.

 

Means for disconnection from the 

supply mains should have a contact separation in all poles 
that provide full disconnection under overvoltage category III 
conditions. 

The appliance must be supplied through a 

residual current device (RCD) having a rated residual 
operating current not exceeding 30mA.

 This appliance is 

not intended for use by young children or infirm persons 
without supervision.

AM
PM

OFF

ON

°C

°F

MODE

SPD

BRT

SAT SUN MON TUE WED THU FRI

38.00

S.TMP Display Mode Icon

Set Water Temperature

W.TMP Display Mode

TIME Display Mode

AM
PM

OFF

ON

°C

°F

MODE

SPD

BRT

SAT SUN MON TUE WED THU FRI

37.60

AM

OFF

ON

MODE

SPD

BRT

SAT SUN

 TUE WED THU FRI

 MON

:

1000

SV-2T

1

3

4

9

8

5

6

7

10

11

12

13

2

Отзывы: