background image

CLEANING AND CHANGING THE FILTER 

 

 

Cleaning /change of filter AquaKing For a good water hygiene it is very important 
that the filter gets cleaned on a regular basis. At least every second week it should be 
rinsed. Every second month or whenever it is required it needs to get cleaned 
“thoroughly” with a special  solution. 
1.

 

Open the hatch where filter and circulation pump are placed. Start the pump 
(keep the T/A button pressed until it starts) if it’s not already running. 

2.

 

Open the screw (1) for the air above the filter top piece. Close the valve (3) on 
the right side of the filter by pressing it down.  

3.

 

Be prepared to close the valve (C) (the one closest to the bottom to the left of 
the pump) when the pump stops. This is important to do, so water will not flow 
back into the filter cartridge holder.  

4.

 

Unscrew the nut and take off the filter’s top piece. Now it is possible to clean the 
filter. It would be good to have a spare one. Assemble it in an opposite order 
(tighten the nut on the cartridge holder, leave it slightly loose so it will be easier 
to reopen it). Tighten the nuts of the filter container properly. Open 1 & 2 and let 
air escape. Close when water starts trickling out. Now the pump can be started 
via the control panel.   

Draining of water  There is a valve (V) close to the circulation pump installed in 
order to drain water, see picture to the right. In case the spa bath needs to be 
emptied for a longer period or if there might be a risk of frost then please keep in 
mind to empty the circulation pump and the massage pump (if included) very 
carefully as well. 
1.

 

Open cover where filter and pump(s) are installed. Open valve (V) and drain the 
water via the drain hole. 

2.

 

Loosen the lowest nut belonging to the pumps (A). This one does not to be 
loosened totally, just so that water can drain. Please do the same with the nuts 
of the filter (B) and please do keep them open. 

3.

 

Loosen the nuts which are connected to the bubble system and give the hose a 
good blow a few times till water runs out.   

4.

 

NOTE! If the control systems model nr. Is TM42-A1 then the blower air pump 
can be started via the control panel. Let it run for a few seconds before turning it 
off again. 

Attention! When the spa is to be drained of water for a longer period of time, or if 
there is a risk of freezing then the circulating pump, massage pumps and nuts for 
pumps and filters shall be left open. If draining is done only for changing the water it 
is not necessary to drain the pumps of water or open these connections. Also read “Avoid damage from freezing”. 

Avoid damage from freezing 

 

Plan the draining and filling of water so that there is no risk of damage from freezing, never empty or fill the bath when the temperature’s 
below freezing without first protecting the equipment. 

 

Attention! If the bath has been emptied of water and the temperature’s below freezing then all the equipment will also be below freezing 
itself- If the bath is filled with water then without considering this, the risks of freezing damage is great. 

 

For protection against freezing damages the interior of the bath can be warmed up beforehand. Use for instance an interior car heater or 
electric heater and set the temp to 20 degrees celsius and place it inside the box where the pumps are installed as well. 

 

If the water level drops below the massage nozzles they are automatically drained of water when the air regulator on the the edge is in 
open moden. Is the air regulator is closed then water can remain in the transparent 12 mm hoses and cause freezing damage. Always 
keep the air regulator in open mode when draining the spa. 

 

To protect BactiSafe against damage from freezing it should be drained by loosening the stainless nut and the sealing around the glass 
tube. 

Содержание Polar AquaKing

Страница 1: ...ired A service switch which is closely installed to the electrical connection is recommended ATTENTION If the hot tub will be integrated e g into a terrace it is necessary that the access is not obstructed in any way order to be able to service it Service hatch and outer panel should be removable without difficulties If automatic dispensers floating etc are used careful adjustment should be made t...

Страница 2: ...F F G G H H Article Polar Part Number AquaKing Material LunaWood Page Size A4 Designed by JI 31 01 11 Checked by Aproved by Scale 1 18 Revision v 2 4 Sheet 23 23 1114 626 394 2248 2570 2289 2620 1635 1920 Water drainage and electric wiring 850 210 200 Hose Ø 33 mm 1814 5 2057 ...

Страница 3: ...1 2 3 4 ...

Страница 4: ...5 6 7 8 ...

Страница 5: ...ane will be applied between the side insulation of the spa bath and the boxe s insulation see picture The insulation beneath the lid of the box should not be used when the temeprature indicates more than 10 degrees To protect BactiSafe against damage from freezing it should be drained by loosening the stainless nut and the sealing around the glass tube Lowering into terrace ATTENTION If the hot tu...

Страница 6: ...e system is ready for testing open the air screw 1 on top of the filter holder and the nut 2 Close it again when water begins to leak out After this procedure the system is ready for use Do not start the system without any water running and watch out that both the tap next to the filter suction side as well as the tap on the pressure side are open meaning the part connected to the pump not the dra...

Страница 7: ...ly just so that water can drain Please do the same with the nuts of the filter B and please do keep them open 3 Loosen the nuts which are connected to the bubble system and give the hose a good blow a few times till water runs out 4 NOTE If the control systems model nr Is TM42 A1 then the blower air pump can be started via the control panel Let it run for a few seconds before turning it off again ...

Страница 8: ...efully before beginning the installation C We are not responsible if the product does not work or is damaged when the instructions are not followed during installation D Ensure that the system is not damaged during transportation when it is unpacked Note A 1 x 16A Read Interlocked system between the heater and pumps 2 x 16A or 3 x 16 should be connected to the control system Do not connect the pow...

Страница 9: ... LAMP key When the control systems are ready to work first press the key Its symbol will now appear on the panel signifying that the underwater lights are on the colour will change automatically with a second press the color will be fixed on a certain color press for the third time to shut it off NOTE The lamp shuts off automatically after 60 minutes TEMP key needs to be used together with key If ...

Страница 10: ...ituations Water lacking protection system for circulation pump and heater In daily usage a blockage of the filtration medium cartridge filter or filter bag will eventually occur A severe blockage will lead to a lack of water for the filtration pump Air in the system often leads to the same problem For instance during startup if aeration has not been performed according to the instructions in the m...

Страница 11: ...rature is higher than the actual water temperature then both the circulation pump and heater are activated until the water temperature reaches the chosen setting The Ozone will automatically work together with the filtration pump and heater This applies in both and modes WARNING The circulation pump also generates heat and if it is running a long time eg continuous filtration it can raise the temp...

Отзывы: