11.2 Inflation pedal (on demand)
The pressure on the inflation pedal and the keeping it
pressed, delivers air at controlled pressure (max 4,2
± 0,2 bar).
DO NOT CHANGE THE SET OP-
ERATING PRESSURE VALUE BY
MEANS OF THE MAXIMUM PRES-
SURE VALVES. THE MANUFAC-
TURER SHALL NOT BE RESPON-
SIBLE FOR INJURY OR DAMAGE
ARISING FROM UNAUTHORISED
CHANGES.
11.0 CONTROLS
The pedal control unit comprises 5 (five) pedals.
11.1 5 pedals control unit
“Pedal 1”
on this type of pedal control unit activates
the automatic post and has two fixed operative func-
tions:
the first one (with pedal up) overturns the post from
the operator's opposite side; the second one (with pedal
down) brings back the post to working position.
“Pedal 2”
opens and closes the locking jaws of the
self-centering device. It has three stable positions:
open – close – approach jaws.
“Pedal 3”
controls turntable rotation and has 3 stable
positions:
1. 0 position, turntable stopped;
2. Pressed down, the turntable is rotated clockwise;
3. Raised, the turntable is rotated anti-clockwise.
ONLY FOR VERSIONS WITH THREE-
PHASE 230/400 V - 50 HZ 2 SPEED
“Pedal 3”
controls turntable rotation and has 4 stable
positions:
1. 0 position, turntable stopped;
2. Position 1 downwards - clockwise rotation of turn-
table;
3. Position 2 downwards from position 1 - clockwise
rotation of turntable at double speed;
4. Position 1 upwards - counterclockwise rotation of
turntable;
“Pedal 4”
has 2 operative positions: when it is pressed
downwards, the cylinder for bead breaking with lateral
arm (A) is operated; when such pedal is released, the
bead breaking arm is moved back to the initial position
(open bead breaker) (B).
The inflation
“pedal 5”
(only for “I” and “IT” versions)
has three positions:
1. completely lowered “unstable”: to cause air (con-
tained in the reservoir) to be jetted out through air
lances;
2. middle stroke “unstable” position: it lets air out
from inflating head;
3. released “stable” position: it closes air outlets.
DO NOT CHANGE THE SET OP-
ERATING PRESSURE VALUE BY
MEANS OF THE MAXIMUM PRES-
SURE VALVES. THE MANUFAC-
TURER SHALL NOT BE RESPON-
SIBLE FOR INJURY OR DAMAGE
ARISING FROM UNAUTHORISED
CHANGES.