Form 43343110
May 2021
-55-
1.
Open hinged access panel.
2.
Add tubing to connect the air switch tubing P1 + and P2 - with the connector tees and the probes P1+ and
P2+.
3.
Connect plastic tubing of a digital or inclined water manometer with a 0-
2” scale o
nto the connector tees.
4.
Turn heater on and wait until blower motor is activated.
5.
Observe air pressure from manometer. This should be higher than the set point indicated below for correct
operation.
Model
Operating Pressure
PCA-SS 75
0.70” W.C. Hot
PCA-SS 100
0.8
0” W.C
. Hot
PCA-SS 125
0.39” W.C. Hot
PCA-SS 150
0.39” W.C. Hot
All pressures are with the heater in operation for at least 15 minutes.
20.4)
IGNITION SYSTEM CHECKS
TO CHECK FLAME SENSOR CIRCUIT.
Flame current is the current which passes through the flame from the sensor to ground. The minimum flame
current necessary to keep the system from lockout is 0.7 microamps.
a.
Turn off heater at thermostat.
b.
Connect a meter (dc microammeter scale) in series with the ground lead as shown in the diagram. Connect
the meter as follows:
•
Connect the black (negative) meter lead to the electronic control FC- terminal.
•
Connect the red (positive) meter lead to the electronic control FC+ terminal.
c.
Restart the system and read the meter. The flame sensor current must be steady and measure at least 0.7
microamps.
d.
If the meter reads less than the minimum or if reading is unsteady:
•
Make sure burner flame is capable of providing a good rectification signal.
•
Make sure fasteners securing igniter/sensor are tightened to assure correct positions. DO NOT relocate
igniter/sensor.
•
Check for excessive (over 1000ºF) temperature at ceramic insulator on flame sensor. Excessive
temperature can cause short to ground. DO NOT relocate igniter/sensor.
•
Check for cracked ceramic insulator, which can cause short to ground, and replace sensor if necessary.
•
Make sure that electrical connections are clean and tight. Replace damaged wire.
e.
If the meter reads below “0” o
n the scale, meter leads are reversed. Disconnect power and reconnect meter
leads for proper polarity.
f.
Remove microammeter. Return system to normal operation.
Содержание PCA-SS 100
Страница 13: ...Form 43343110 12 May 2021 7 1 DIMENSIONS STRAIGHT CONFIGURATION 48 HANGING CENTERS...
Страница 14: ...Form 43343110 May 2021 13 7 2 HEATER ASSEMBLY JOINING OF TUBE SECTIONS...
Страница 21: ...Form 43343110 20 May 2021...
Страница 48: ...Form 43343110 May 2021 47 19 0 TROUBLESHOOTING GUIDE SINGLE STAGE N5 L5...
Страница 49: ...Form 43343110 48 May 2021 TROUBLESHOOTING GUIDE SINGLE STAGE CONTINUED...
Страница 50: ...Form 43343110 May 2021 49 TROUBLESHOOTING GUIDE SINGLE STAGE CONTINUED...
Страница 51: ...Form 43343110 50 May 2021 19 1 TROUBLESHOOTING GUIDE TWO STAGE N7 L7...
Страница 52: ...Form 43343110 May 2021 51 TROUBLESHOOTING GUIDE TWO STAGE CONTINUED...
Страница 53: ...Form 43343110 52 May 2021 TROUBLESHOOTING GUIDE TWO STAGE CONTINUED...
Страница 55: ...Form 43343110 54 May 2021 20 2 REMOVING GAS VALVE AND MANIFOLD ASSEMBLY 20 3 AIR SWITCH PRESSURE CHECK...