7.6
Replacing the limit stop distance plate
Replacing the limit stop distance plate
Step 1:
Turn off the mains switch on the device, disconnect the main air
supply and remove the cover hood.
Step 2:
Remove the limit stop distance plate (a) by opening the tommy
screw (b).
Step 3:
Remove the required limit stop distance plate from the conversion
set.
Each limit stop distance plate is labelled with the stud diameter
for which it must be used (a).
Step 4:
Attach the limit stop distance plate (a) and clamp it with the tommy
screw (b).