7.3
Adjusting the step width
The step width is the width of the spiral-shaped upward steps in the feeder bowl. The
continuous adjustment of the step width guarantees the separation of adjacent studs
which would cause a malfunction if they reached the outlet rails.
Adjusting the step width
Step 1:
Turn off the mains switch on the device, disconnect the main air
supply and remove the cover hood.
Step 2:
To adjust the step width, there is an adjustable plate (a) on the feeder
bowl.
To adjust the plate, loosen both clamp screws (b).
Step 3:
Adjust the plate so that only one stud can lie across the whole retainer
surface (a). Studs which are parallel to one another or on top of one
another (b) will then fall off the plate.
After the adjustment, retighten the clamp screws (c).
The step width is adjusted.