Soyal AR-721E Скачать руководство пользователя страница 1

SOYAL

ACCESS CONTROL SYSTEM

®

AR-721E

V100630

    

    

   

1

ON

2 3 4

1

ON

off

ON

ON

off

2

off

ON
ON

ON

off

3

off
off
off

ON

off

4

off
off
off

ON

off

~

AR-321H

   

4 3 2 1

AR-721E

P4

COM

COM

12V

GND

COM
OUT1
BZ
LG
LR
TAM
SEN
PB
WD1
WD0
GND
12V

LA+
LB-
GND
DC 12V

COM
DI2
DI1

COM
OUT2
BZ
LG
LR
TAM
SEN
PB
WD1
WD0
GND
12V

COM
DO1
COM
ALM

DO3
DO2

4 3 2 1

P1

12V

12V

GND

B-

B-

A+

A+

AR-721E

1

ON

2 3 4

4 3 2 1

4 3 2 1

12 11 10 9 8 7 6 5 4 3 2 1

12 11 10 9 8 7 6 5 4 3 2 1

2 1

3 2 1

Dip-switch

N.O.

N.O.

N.O.

N.O.

OUT 1

ALM

OUT 2

DO 1

P1

P2

P3

P5

P6

P4

Contents

Specifi cation

1

Product

3

Specifi cation

Separate controller connected to 2 WG readers, can enhance the security of the system.
Can connect to Door Open Button, Door Sensor, and Tamper Switch.
When Door open to Long or Force open, it's can be detected.

4 Control Mode, allowing users the fl exibility of use with.

Can automatically determine to use stand-alone or networking.

2

User Guide

CPU
RAM
Power Supply
Power Consumption
Interface
Baud Rate

External WG Readers

8 bit CPU 
512 k Bits
10 ~ 24
< 3W 
RS-485
9600 bps,N,8,1
2 WG 

(Controller power supply)

20

℃ ~ +

60

2 Door Open Button/ 2 Door Sensor/ 2 Housing open detection/ Prepared for 2 DI
2 Door Relay/ 1 Alarm Relay/ Prepared for 1 Relay output
Prepared for 2 DO
Toggle, 0.1~600Ses
Toggle,

 

0.1~600Ses

3,000

1456
WG 26 / WG 34
YES 
NO
63 

(stand-alone /networking)

YES

(Node ID: 1~16) 

Temperature
Digital Input
Relpy Output
Transistor Output
Door Relay Time
Alarm Relay Time
User Capacity

Event log

Aux. WG Port

Anti-pass-back
Lift Control
Time Zone
Real Time Clock
DIP_SW

P1

Connector:

P2

Connector:

P3

Connector:

P4

Connector:

P5

Connector:

P6

Connector:

Code

Code

Code

Code

Code

Code

Pin

1
2

Pin

1
2
3

Pin

1
2
3
4
5
6
7
8
9

10

11

12

Pin

1
2
3
4
5
6
7
8
9

10

11

12

Pin

1
2
3
4

Pin

1
2
3
4

Description

DO 3
DO 2

Description

COM
DI 2
Fire-alarm Input 

Description

COM
N.C./N.O.
Beeper Output 
LED Green Output
LED Red Output
N.C.
N.C.
N.O.
Wiegand DAT:1 Input
Wiegand DAT:0 Input
DC Power 0V Output
DC Power 12V Output

Description

COM
N.C./N.O.
Beeper Output 
LED Green Output
LED Red Output
Tamper Switch Input
Door Sensor Input

Exit Switch Input

Wiegand DAT:1 Input
Wiegand DAT:0 Input
DC Power 0V Output
DC Power 12V Output

Description

RS-485(A+)
RS-485(B-)
DC Power 0V
DC Power 12V

Description

COM
N.C./N.O.
COM
N.C./N.O.

Connector Table

DIP SW
Node ID 01
Node ID 02
Node ID 03

Node ID 15
Node ID 16

Node ID is setting by DIP_Switch
Node ID: 01~16

Connect to PC

P1

Connect to Alarm or Other Equipment

P4

Wiring Diagram

Converter

POWER

12VDC

POWER

12VDC

Alarm

Equipment

Отзывы: