background image

12

Southworth Products

SR-44 Manual

4.2    Electrical Connections

The owner/installer is responsible for providing a fused disconnect 

switch. See section 8.1 Fusing Requirements.
Single phase machines must be connected to a dedicated circuit. 

Operating other equipment on the same circuit can cause excessive 

voltage drops and damage electrical components.

Make all connections according the wiring schematic. 

See section 8.2 Wiring Schematics.

4.3    Control Station

The control is shipped pre-wired to the machine. The control station must be placed in a location 

that allows the operator to see the load during operation but does not interfere with loading, 

unloading, and operation.

Mount the control station to the floor using the four mounting holes in the base plate. Anchors to 

be provided by installer.

4.4    Testing

Ensure all tools, personnel, and debris are clear of the area. 
During operation the movements should be smooth. Some bouncing/

stuttering may occur during initial operation caused by air in the 

hydraulic system. The air will bleed out of the system after several 

cycles. 
If the machine does not begin to rotate/clamp within several seconds of 

pressing the button, immediately release the button and consult section 

7. Troubleshooting.
Verify the maintenance chains are disengaged before operating the 

machine.

1.  Disengage the maintenance chains.
2.  Turn on the main disconnect switch to power the machine.
3.  Verify all personnel and debris are clear of the machine.
4. 

Press and hold the “Rotate CW” button. While the machine is rotating, press the emergency 

stop button. The machine should stop rotating and no longer function.

5.  Verify the machine is completely disabled by pressing each control button, the machine 

must not operate while the emergency stop is activated.

6. 

Reset the emergency stop button. Press and hold the “Rotate CW” button until the rotator 

mechanism reaches the end of travel.

7. 

Press and hold the “Rotate CCW” button until the rotator mechanism reaches the end of 

travel. Immediately release the button once the end of travel is reached. Allow the machine 

to rest for one minute. The machine should holds it position.

8. 

Press and hold the “Clamp” button until the clamp mechanism is fully clamped. Immediately 

release the button once the mechanism is fully clamped. Allow the machine to rest for one 

minute. The machine should hold its position.

9. 

Press and hold the “Unclamp” button until mechanism is fully opened. Immediately release 

the button once the mechanism is fully opened.

Содержание SR-44 Series

Страница 1: ...anual SOUTHWORTH PRODUCTS CORP P O Box 1380 Portland ME 04104 1380 Telephone 800 743 1000 207 878 0700 Fax 207 797 4734 www SouthworthProducts com Model SR 44 Serial Number __________________________...

Страница 2: ...ections 12 4 3 Control Station 12 4 4 Testing 12 5 Operation 14 5 1 Before Each Use 14 5 2 Loading 14 5 2 1 Load Restrictions 14 5 3 Operation Instructions 15 6 Maintenance Repair 16 6 1 Periodic Main...

Страница 3: ...SR 44 Manual This label part 10095524 is required by California law For more information visit www 65Warnings ca gov This label part 10095524 is required by California law For more information visit w...

Страница 4: ...as applicable 1 Remove the load from the platform 2 Rotate the clamp mechanism to the maintenance position and secure using the maintenance chains 3 Relieve system pressure from all circuits before lo...

Страница 5: ...ting the operation of the machine 3 Factors affecting stability 4 The purpose of placards and decals 5 Workplace inspection 6 Safety rules and regulations 7 Authorization to operate 8 Operator warning...

Страница 6: ...to comply with the safety standards established for the workplace 6 Reporting problems or malfunctions The operator shall immediately report to a supervisor any problem s or malfunction s that become...

Страница 7: ...ignal words D is a safety yellow triangle with a safety black border and safety black exclamation mark 2 2 Signal Words DANGER Indicates a hazardous situation that if not avoided will result in death...

Страница 8: ...Diagram FROM PLUG MACHINES ONLY PLACE ON POWE 10021381 TO BE APPLIED TO 115 1 12 1 2 3 3 13 2 1 3 3 1 11 1 1 ITEM NO M U Y T Q 13 1 EA LD WARNING CANC 12 1 EA BK LD DCL 2 50X12 7 11 4 EA LD DCL 1 50X6...

Страница 9: ...0047672 6 2 EA BK LD DCL 1 25X1 75 POWER 5 2 EA BK LD DCL 1 25X1 75 CONTROL 4 1 EA LD DCL 4 50X8 00 CLOCKWISE FOR HIGHER CL 10039039 3 4 EA LD DCL 1 25X2 75 CAPACITY 4400 LBS 10039022 2 2 EA LD DCL 2...

Страница 10: ...ing do not install in an area where flammable materials are present This machine must be installed and operated indoors and in an area protected from rain and moisture Do not sit stand or ride on the...

Страница 11: ...h to clear the shipping skid and transport the machine to the desired location 5 Carefully lower the machine onto the floor If anchoring the machine 6 Mark the locations of the four anchor points loca...

Страница 12: ...ds of pressing the button immediately release the button and consult section 7 Troubleshooting Verify the maintenance chains are disengaged before operating the machine 1 Disengage the maintenance cha...

Страница 13: ...13 Press and hold the Clamp button until the load is secure Pay close attention while clamping the load The load must be clamped enough to secure it from falling during rotation If necessary clamping...

Страница 14: ...excessive wear or damage Verify all precautionary labeling is in place and legible Inspect controls and cords for damage Inspect for hydraulic leaks and loose fittings Inspect controller and cord for...

Страница 15: ...adjustment knob located on the rear panel of the machine Turn knob clockwise to increase pressure counter clockwise to decrease pressure 4 Press and hold the Rotate CW or Rotate CCW buttons to rotate...

Страница 16: ...in the guardrails unless the machine has been secured with the maintenance chains and the machine has been de energized Ensure maintenance chains are removed prior to operation Before performing maint...

Страница 17: ...the tank with the machine in the maintenance position and clamp mechanism fully opened Grease the pivot assembly using the grease points located on the either side of the mast Apply a dry PTFE lubrica...

Страница 18: ...and hydraulic cylinder for damage The machine will not clamp or rotate motor runs Hydraulic fluid level may be low Check the hydraulic fluid level Add fluid as necessary See section 9 Hydraulics Maint...

Страница 19: ...circuit breaker requirements Nominal Supply Power Full Load Amps Required Breaker 115 1 60 27 30 208 1 60 14 3 20 230 1 60 13 5 20 208 3 60 8 4 15 230 3 60 8 15 460 3 60 4 15 190 3 50 9 4 15 380 3 50...

Страница 20: ...2 1 Single Phase Wiring Schematic 1 4 CLAMP E STOP UNCLAMP ROTATE CW ROTATE CCW 2 M1 MOTOR STARTER 4 1 1 1 1 1 1 1 1 1 4 115 208 230V NOTES SUPPLY POWER CONNECTS TO 1L1 3L2 AT TOP OF MOTOR CONTACTOR S...

Страница 21: ...21 Southworth Products SR 44 Manual 8 2 2 Three Phase Wiring Diagram NOTES SUPPLY PHASES CONNECT TO 1L1 3L2 5L3 AT TOP OF MOTOR CONTACTOR SUPPLY GROUND CONNECTS TO GROUNDING TERMINAL IN CONTROL PANEL...

Страница 22: ...in the maintenance position with maintenance chains engaged and clamp mechanism fully opened When adding fluid cycle the machine through a full clockwise and counterclockwise rotation and full clamp...

Страница 23: ...23 Southworth Products SR 44 Manual 9 2 Hydraulic Schematic...

Страница 24: ...er location at Southworth s discretion This is buyer s sole remedy under any such warranty sale agreement or contract Southworth will not be liable for consequential incidental exemplary or punitive d...

Отзывы: