![Southco EA-P1 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/southco/ea-p1/ea-p1_operating-instructions_1337052001.webp)
EA-P1 Proximity Controller
Operating Instructions
J-EA-P1-01-M_revD
visit
www.southco.com
for latest version of this document
Page 1 of 4
Package Contents
Stand alone PIN + Prox Controller
Operating instructions
Wire harness for JA door access connector (9-wires with
blue connector)
Wire harness for JB lockout alarm connector (8-wires with
white connector)
Wire harness for JC tamper switch connector (3-wires with
blue connector)
Wire harness for JD external Wiegand reader connector (4-
wires with white connector)
Diode (IN4007GW)
2 mounting screws
EA-P1-01x Standalone Proximity Controller
1
2
3
4
1
2
3
4
1.
Power ON LED
2.
Bicolor (red/green) Status LED
3.
PIN + Prox Controller
4.
Return to Ready State
Features
Supports up to 9,999 user cards and five PIN codes
Multiple modes of operation: card-only, card or PIN, card
and PIN, bypass mode
Programmable door release time (1 to 98 seconds)
Programmable failed attempts (1 to 99)
Programmable lockout time (1 to 98 seconds)
Programmable user and supervisor code length (4 to 8
digits)
LED indicators: Power and Status
Supports connection to an external 26-bit Wiegand reader
Non-volatile memory will retain data when power is removed
Tamper switch
For indoor use only
Controller Mounting and Installation
Please refer to Southco trade drawing J-EA-P1-01 for mounting and
installation details.
Specifications
User Cards Supported:
9,999
Supervisor Cards Supported: 9
PIN Codes Supported:
5
Power:
12VDC ± 10%
90mA maximum (standby mode), no
attached devices
110mA maximum (operating mode), no
attached devices
Transmit Frequency :
125kHz ASK (EM)
Card Reading Range:
up to 10 cm (depending on installation)
Default Access Time:
4 seconds
Operating Temperature:
0-50 °C
Operating Humidity:
20-90% RH, No condensation
Dimensions:
118 mm x 75 mm x 19 mm
Default Settings
The table below describes the default settings of the EA-P1-01x
controller.
Description
Default Value
Access Time
4 seconds
PIN Code Length
4 digits
Number of Failed Attempts
3
Lockout Alarm Time
60 seconds
Mode of Operation
card only
Enrolling Supervisor Card
To enroll the supervisor card:
1.
Apply power to the unit.
2.
Switch the two DIP switches on the rear of the unit to “ON”.
3.
Hold the supervisor card to the unit. The status LED will
flash red/green if the card has been successfully enrolled.
4.
Switch the two DIP switches on the rear of the unit to their
original positions (“1” and “2”).
To enroll additional supervisor cards, repeat Steps 1-3 above. Note
that the last digit in the bottom right corner of the prox card must be
different for each supervisor card (see below).
NOTE:
Once a supervisor card has been enrolled, it cannot be
deleted.
xxxx
xxxxxxxxxx
01234
56789
last digit