Southco EA-P1 Скачать руководство пользователя страница 1

EA-P1 Proximity Controller

Operating Instructions

J-EA-P1-01-M_revD

visit

www.southco.com

for latest version of this document

Page 1 of 4

Package Contents

Stand alone PIN + Prox Controller

Operating instructions

Wire harness for JA door access connector (9-wires with
blue connector)

Wire harness for JB lockout alarm connector (8-wires with
white connector)

Wire harness for JC tamper switch connector (3-wires with
blue connector)

Wire harness for JD external Wiegand reader connector (4-
wires with white connector)

Diode (IN4007GW)

2 mounting screws

EA-P1-01x Standalone Proximity Controller

1

2

3

4

1

2

3

4

1.

Power ON LED

2.

Bicolor (red/green) Status LED

3.

PIN + Prox Controller

4.

Return to Ready State

Features

Supports up to 9,999 user cards and five PIN codes

Multiple modes of operation: card-only, card or PIN, card
and PIN, bypass mode

Programmable door release time (1 to 98 seconds)

Programmable failed attempts (1 to 99)

Programmable lockout time (1 to 98 seconds)

Programmable user and supervisor code length (4 to 8
digits)

LED indicators: Power and Status

Supports connection to an external 26-bit Wiegand reader

Non-volatile memory will retain data when power is removed

Tamper switch

For indoor use only

Controller Mounting and Installation

Please refer to Southco trade drawing J-EA-P1-01 for mounting and
installation details.

Specifications

User Cards Supported:

9,999

Supervisor Cards Supported: 9
PIN Codes Supported:

5

Power:

12VDC ± 10%
90mA maximum (standby mode), no
attached devices
110mA maximum (operating mode), no
attached devices

Transmit Frequency :

125kHz ASK (EM)

Card Reading Range:

up to 10 cm (depending on installation)

Default Access Time:

4 seconds

Operating Temperature:

0-50 °C

Operating Humidity:

20-90% RH, No condensation

Dimensions:

118 mm x 75 mm x 19 mm

Default Settings

The table below describes the default settings of the EA-P1-01x
controller.

Description

Default Value

Access Time

4 seconds

PIN Code Length

4 digits

Number of Failed Attempts

3

Lockout Alarm Time

60 seconds

Mode of Operation

card only

Enrolling Supervisor Card

To enroll the supervisor card:

1.

Apply power to the unit.

2.

Switch the two DIP switches on the rear of the unit to “ON”.

3.

Hold the supervisor card to the unit. The status LED will
flash red/green if the card has been successfully enrolled.

4.

Switch the two DIP switches on the rear of the unit to their
original positions (“1” and “2”).

To enroll additional supervisor cards, repeat Steps 1-3 above. Note
that the last digit in the bottom right corner of the prox card must be
different for each supervisor card (see below).

NOTE:

Once a supervisor card has been enrolled, it cannot be

deleted.

xxxx

xxxxxxxxxx

01234

56789

last digit