I
NSTALLATION
S
TRATO
S
TEAM
E
LECTRIC
C
OUNTERTOP
S
TEAMER
P
AGE
16
OF
56 O
WNER
’
S
M
ANUAL
1189951
(10/08)
Figure 7
Water Drain
90°
Air Gap
Air Gap
Air Gap
Stand
Pipe
Floor Drains
S
TEP
4:
W
ATER
C
ONNECTION
WARNING
Do not connect steamer to a hot water line. A hot water connection will damage the steamer.
NOTICE
To meet warranty requirements, the supply water must meet the following specifications:
Pressure
30 to 60 PSI (205 to 410 kPa)
Total Dissolved Solids (TDS)
60 PPM or less
Hardness
2 grains (35 PPM) or less
pH
7.0 to 7.5
Chlorine and/or bromine
1 PPM or less
Connect a cold water line to the water inlet strainer on the back of the steamer, as shown in Figure 6. The connector
on the steamer is a 1/4" (6 mm) compression fitting. (If the unit was ordered with the split-water-line option, connect
the treated-water supply to the lower inlet, and the regular-water supply to the upper inlet.)
NOTE: To facilitate cleaning, and allow access to rear of the steamer, flexible connections are recommended. A shut
off valve at (or near) the rear of the steamer is highly recommended. Also, an accessible water filter is recommended
to help keep water quality within the requirements described above. See Figure 8 below.
Figure 8
Water Connection
Filter
Steamer
Cold
Water
Supply
Shut Off
Valve
Содержание StratoSteam STRE-3D
Страница 53: ...STRATOSTEAM ELECTRIC COUNTERTOP STEAMER OWNER S MANUAL 1189951 10 08 PAGE 53 OF 56 Notes...
Страница 54: ...STRATOSTEAM ELECTRIC COUNTERTOP STEAMER PAGE 54 OF 56 OWNER S MANUAL 1189951 10 08 Notes...
Страница 55: ...STRATOSTEAM ELECTRIC COUNTERTOP STEAMER OWNER S MANUAL 1189951 10 08 PAGE 55 OF 56 Notes...