Quick-Check-PowerSaver Manifold 6 Port South-Tek Systems
Revision: 0
Revision Date: 8/2/17
Page 24 of 30
NOTE: If the generator or any part of the system has been opened to the atmosphere or water, the system must be
purged of any residual air/water to get within the limits of the purity setpoint. Another “Initial System Purge” is
advised.
7.2
SHUTDOWN
For normal shutdown, toggle the “ON/OFF” button to OFF on the “Home” screen.
WARNING: The Quick-Check-PowerSaver Manifold will remain pressurized after shutdown. Before performing any
maintenance or opening any piping systems, always depressurize the system. Failure to do so may result in injuries.
8
SYSTEM MAINTENANCE
8.1
FILTER ELEMENT REPLACEMENT
All units come equipped with a pre-analyzer filter. Clean filter elements are important for good system performance.
Factory recommendation on filter change out schedule are as follows:
-Pre-analyzer filter: 12 months (Once per year)
See instructions below for how to remove/replace the filter element.
WARNING: Do not try to remove filter bowls until the filter is completely
depressurized. Valve off the incoming gas supply by turning the selector
switch on the main screen to the OFF position.
1.
Disconnect the tubes from the bottom of the bowls (if tied into
condensate drain system).
2.
To remove the bowl, turn the metal casing around the clear
blue plastic bowl counter-clockwise until it unscrews completely
from the housing. Then twist slightly and pull the blue plastic
bowl downwards out of the housing.
3.
Inspect the bowls. If the drain system is working properly, the
bowls should not be full of water.
4.
Remove the filter element by carefully pulling the black plastic
filter element holder out of the filter bowl and twisting the top
and bottom piece counter-clockwise until the holder pulls
apart. Take notice of how the element looks. If the element is
excessively dirty, more frequent filter changes are
recommended.
Figure 21: Filter Replacement