Quick-Check-PowerSaver Manifold 6 Port South-Tek Systems
Revision: 0
Revision Date: 8/2/17
Page 10 of 30
Until Installation:
Store the Quick-Check in a dry and climate controlled (60-80°F) room.
Always keep Quick-Check in a safe place / or in box as shipped.
Do not connect power until manual has been read completely and all connections are made as stated
within.
Keep all pipes and APS lines dry so moisture does not enter Quick-Check upon hookup.
Never place/stack objects on top of the Quick-Check.
3.2
STORAGE INSTRUCTIONS
If the unit is not to be installed until a later date, a safe dry storage location is needed - preferably inside a controlled
environment. Place desiccant packets into the electrical cabinet to keep moisture from damaging the electronics. Do
not store around moving objects that could fall or damage the unit. If the unit is kept in storage for an extended time
(over 1 month), then the Oxygen Fuel Cell/Analyzer (if included) should be removed, sealed off, and stored in a
controlled environment.
3.3
ELECTRICAL REQUIREMENTS
Power supply must be 110 V or 220 V / 1 ph / 50 - 60 Hz as labeled on the unit. Operating amp draw is less than 2
amps. The Quick-Check must be hardwired unless otherwise specified in the customer installation drawings. The
internal control panel is a UL 508A Open Industrial Control Panel approved with a 7 Amp time delay fuse. Electronic
copy of the electrical schematic is available upon request.
Note: Always obey all local and site codes to finalize power connection to the equipment.
4
SYSTEM DESCRIPTION
4.1
KEY FEATURES
The Quick-Check-PowerSaver Manifold and all components are securely packed to minimize possibilities of damages
during shipment. The contents of the shipment should be inspected upon delivery to assure that no damage has
(Connect electrical supply
according to dotted area)
Figure 1: Customer Electrical Connection to Quick-Check PowerSaver Manifold