BeerBlast™ 7/14KPH & N
2
-GEN
™ 7/14KPH O&M
South-Tek Systems
23
1.
The
BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH
is supplied with
½” NPT Female inlet and outlet fittings. Make
sure to use Teflon tape or similar on all fittings to make sure they d
on’t leak.
2.
Connect the BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH
to the storage tank and then to the beer system.
3.
Once connections are made, slowly open the Syst
em’s On/Off Valve.
A.
You will hear air rushing through the system and N
2
filling the
BeerBlast™ 7/14KPH / N
2
-
GEN™
7/14KPH storage tank.
B.
If you hear a leak or have a bad connection, shut the valve off and make the correction.
C.
If there is a leak within the unit, remove the cover and locate the issue. If you have to replace any
parts, only use factory parts supplied from your distributor or South-Tek Systems. Consult the
factory if there are any questions.
4.
Once the BeerBlast™ 7/14KPH / N2-GEN™ 7/14KPH fills the 100# storage tank to 70 PSIG, the system will enter
standby
– the system’s green N2 Production light will change to orange indicating that the system is in standby.
This will shut the air flow off through the generator and eventually shutting off the air compressor once it
reaches air tank cutout pressure.
A.
This will save air and time on your compressor
’s motor.
B.
This also prolongs life of nitrogen generator
’s media and filter life.
i.
Lesser quality systems have a constant purge flow through their systems which
decreases system life and increases the need for maintenance.
5.
When you draw N
2
off the system and the tank pressure falls below cut-in pressure (approximately 62
PSIG), the pressure switch will trigger the system back into run mode and start recharging the storage tank
automatically. The pressure switch is preset at the factory
– no field adjustment is required.
4.10
CHECKING FOR LEAKS
When a leak is suspected, first try to listen for leaks around the connection ports. If a leak is found, isolate the area
so that there’s no pressure on it. Fix the leaking part and return the system back to operation. If no leak can be
heard, turn off the unit and try isolating sections to see if there’s a pressure loss. If the BlastOff™ option is included
with your unit, the system will alarm indicating that there is a leak in the line. Consult with your installer if you
cannot locate the leakage area.
To determine if the leak is within the cabinet:
1.
With the unit powered on, close off all output gas. If no ball valve is installed on the output ports, it is
recommended to remove the gas lines and install a plug.
2.
Allow the system to continue running. Within 1 hour, the system should reach the “Standby” mode.
3.
Wait for 5 minutes
and if the system remains in the “standby” mode, then the leak is after this point.
Check the gas lines exterior to the cabinet all the way back to the keg system.
4.
If the unit goes back into “run” mode, the leak is within the cabinet. Check all the lines going to the
blender and back to the tank.
To find the leak within the cabinet:
1.
Open the front cabinet door and locate the N
2
storage tank.
2.
Close off the output ball valve from the tank (upper ball valve on the red manifold).
3.
Watch the exterior gauge above the cabinet for 60 seconds. If you see the pressure dropping, the
leak is somewhere between the output ports, to the blender (if one is present), and back to the closed
off ball valve on the tank. Fill and/or listen for leaks and fix them once found. If the pressure is not
dropping go to the next step.
4.
With the unit still running, close off the input ball valve to the tank (lower ball valve on the red
manifold).
5.
Within 5 minutes, the system should go into
“Standby” Mode. If it doesn’t, contact your local
provider/installer for further assistance.
6.
Once in
“Standby” mode, wait 60 seconds. After 60 seconds, the system should remain in “standby”
mode. If it doesn’t, leak is somewhere between the check valve and the output ball valve on the tank.
7.
If the system remains in standby, contact your local provider/installer for further assistance.
Содержание BEERBLAST 14KPH
Страница 3: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 3 Notes Page ...
Страница 5: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 5 Notes ...
Страница 16: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 16 ...
Страница 17: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 17 ...
Страница 19: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 19 Figure 1 100 N2 Storage Tank Setup ...
Страница 31: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 31 Last Page ...