-22-
For Machines Mfd. Since 10/20
South Bend Tools
Model SB1100 & SB1101
P R E P A R A T I O N
Test Run
After all preparation steps have been completed,
the machine and its safety features must be
tested to ensure correct operation. If you discover
a problem with the operation of the machine or
its safety components, do not operate it further
until you have resolved the problem.
Note:
Refer to Troubleshooting on Page 42
for solutions to common problems. If you need
additional help, contact our Tech Support at
(360) 734-1540.
The test run consists of verifying the following:
• Motor powers up and runs correctly.
• Emergency Stop button works correctly.
• Remote control works correctly.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine may
result in malfunction or unexpected results
that can lead to serious injury, death, or
machine/property damage.
Serious injury or death can result from using
this machine BEFORE understanding its
controls and related safety information. DO
NOT operate, or allow others to operate,
machine until the information is understood.
4.
Press Emergency Stop button in.
5.
Connect machine to power.
6.
Twist Emergency Stop button clockwise until
it springs out (see Figure 32). This resets
the switch so the machine can start.
Figure 32. Resetting the switch.
7.
Standing away from intake port, press green
Start button to turn machine ON. Verify
motor starts up and runs smoothly without
any problems or unusual noises.
8.
Press Emergency Stop button to turn
machine OFF.
9.
WITHOUT resetting Emergency Stop
button, try to start machine by pressing the
green Start button. The machine should not
start.
— If the machine does not start, the safety
feature of the Emergency Stop button is
working correctly.
— If the machine does start, immediately
turn it OFF and disconnect power. The
safety feature of the Emergency Stop
button is NOT working properly and
must be replaced before further using the
machine.
10.
To test remote control operation, reset
Emergency Stop button then press remote
ON button to turn motor
ON, then press
remote OFF button to turn motor OFF.
— If the machine does NOT start or stop,
press Emergency Stop button to turn
machine
OFF. Refer to Pairing Remote
Control & Receiver on Page 41 and
ensure remote control is paired.
Congratulations! The Test Run is complete.
To test run machine:
1.
Clear all setup tools away from machine.
2.
Lock all swivel casters on base stand.
3.
Connect machine to dust-collection system or
place covers over inlet adapter ports.
IMPORTANT:
DO NOT operate the dust
collector without first connecting it to a dust-
collection system or covering an inlet adapter
port. Otherwise, the lack of airflow resistance
will cause the motor to operate at full
amperage load, which could trip your circuit
breaker or blow a fuse.
Содержание SB1100
Страница 60: ...southbendtools com Printed In U S A AI21261...