Chapter 5 Function parameter
29
No. Code Parameter name
Setting range
Factory
default Change
Reference
page
52.
F1.17 Filter time of AI2
input
0.00s to 10.00s
0.10s
☆
57
53.
F1.18 Times of switching
quantity filtering
1 to 10
5
☆
57
54.
F1.19 DI terminal mode
selection
0x000 to 0x1FF
000
☆
57
5-1-4.F2 Group - Output terminals
No. Code
Parameter name
Setting range
Factory
default Change
Reference
page
55.
F2.00 MO1 output
selection
0: No output
1: Motor forward
running
2: Motor reverse
running
3: Fault output
4: Frequency level
detection FDT
output
5: Frequency
arrival
6: Zero speed
running
7: Upper limit
frequency arrival
8: Lower limit
frequency arrival
9 to 10: Reserved
1
☆
57
56.
F2.01 Reserved
57.
F2.02 Reserved
58.
F2.03 Relay output
selection
1
☆
57
59.
F2.04 AO1 output
selection
0: Running
frequency
1: Set frequency
2: Output current
3: Output torque
4: Output power
5: Output voltage
6: Analog input
AI1 value
7: Analog input
AI2 value
8: Run speed
9 to 10: Reserved
0
☆
58