DE2-EAMSAA100 0519 Pg. 2
1.800.338.7337 / www.soundoffsignal.com
DE2-EAMSAA300 A300 SIREN
INSTALLATION
MOuNTINg
The Armada
®
A300 siren may be mounted above the dash, below
the dash, on a tunnel or in a rack with the mounting bracket and
the hardware supplied. Ease of operation and convenience to the
operator should be the prime consideration when mounting the siren
and controls.
Install the siren on the bracket using the M6x12 bolts and M6 flat
washers & spring washers supplied.
NOTE: Longer bolts will prevent removal of the chassis from the
cover and may damage internal components.
7 POSITION TERMINAL BLOCK CONNECTIONS
+12V
- Connect to a po12 volt DC source. It is
recommended that the user protect this Wire with a 15 Amp fuse or
circuit breaker located at the source. Use #14 gauge wire.
+12V LTg
. - Connect to the positive terminal of the battery with
30 Amp circuit protection. Locate the fuse or circuit breaker at the
battery and use size 10AWG wire minimum.
gRND
- Connect to the negative terminal of the battery. This
supplies ground to the siren. Use #14 gauge wire.
LIgHTINg2
- Connect to the load to be controlled by LIGHTING2
switch, it can supply a maximum of 10 Amps.
LIgHTINg1
- Connect to the load to be controlled by LIGHTING1
switch, it can supply a maximum of 10 Amps.
SPKR
- Connect to one of the wires from speaker.
COM
- Connect to the remaining speaker lead for 100W speaker.
CO
M
.
SPK
R
.
LIGHTING1
LIGHTING2
GRND
+12V L
TG
.
+12
V
.
12V
BATTERY
30 A.
15 A.
100W SPEAKER
MAX 10
A
MAX 10
A
Figure 2 – Control Panel
Figure 1 – Wiring Diagram
AIR HORN
MANUAL
VOLUME
POWER
LIGHTING1 LIGHTING2
STBY
WAIL
YELP
HI-LO
PHSR
MIC
Mic Jack
Rotary Selector Switch
PA Volume Control&
Power Switch
A
Lighting
Control Switch
Power Indicate
Lamp
Air Horn/Manual
Push Switch
MODEL A300