background image

DE2-EAMSAA100   0519  Pg. 2

1.800.338.7337 / www.soundoffsignal.com

DE2-EAMSAA300 A300 SIREN

INSTALLATION

MOuNTINg

The Armada

® 

A300 siren may be mounted above the dash, below 

the dash, on a tunnel or in a rack with the mounting bracket and 

the hardware supplied. Ease of operation and convenience to the 

operator should be the prime consideration when mounting the siren 

and controls.

Install the siren on the bracket using the M6x12 bolts and M6 flat 

washers & spring washers supplied.

NOTE: Longer bolts will prevent removal of the chassis from the 

cover and may damage internal components.

7 POSITION TERMINAL BLOCK CONNECTIONS

+12V

 - Connect to a po12 volt DC source. It is 

recommended that the user protect this Wire with a 15 Amp fuse or 

circuit breaker located at the source. Use #14 gauge wire.

+12V LTg

. - Connect to the positive terminal of the battery with 

30 Amp circuit protection. Locate the fuse or circuit breaker at the 

battery and use size 10AWG wire minimum.

gRND

 - Connect to the negative terminal of the battery. This 

supplies ground to the siren. Use #14 gauge wire.

LIgHTINg2

 - Connect to the load to be controlled by LIGHTING2 

switch, it can supply a maximum of 10 Amps.

LIgHTINg1

 - Connect to the load to be controlled by LIGHTING1 

switch, it can supply a maximum of 10 Amps.

SPKR

 - Connect to one of the wires from speaker.

COM

 - Connect to the remaining speaker lead for 100W speaker.

 

CO

M

SPK

R

LIGHTING1 

LIGHTING2 

GRND 

+12V L

TG

+12

V

12V

BATTERY

30 A. 

15 A. 

100W SPEAKER

MAX 10

A

MAX 10

A

Figure 2 – Control Panel 

Figure 1 – Wiring Diagram

AIR HORN

MANUAL

 

VOLUME

POWER

LIGHTING1  LIGHTING2

STBY

 

WAIL

 

YELP 

HI-LO

PHSR

MIC

Mic Jack 

Rotary Selector Switch

PA Volume Control&

Power Switch 

A

Lighting

Control Switch 

Power Indicate 

Lamp

Air Horn/Manual

Push Switch

MODEL A300