background image

16.AC INLET

      Connect to the supplied power cord.

17.OUT COMMON RELE MUSIC ZONE
18.OUT POWER CONTROL RELE
19.OUT MIX SIGNAL MUSIC VOICE
20.OUT SIGNAL MUSIC
21.OUT SIGNAL VOICE
22.CONTACT PLAY MESSAGE 1 OR 2

      The third message is activated by     
      Microphone basedirectly.  

23. SW

H REC MESSAGE: 

      OF F, 1, 2, 3 .

      This is used to select the message 
      to record

24. SWS

H MESSAGE 1 

       TIME / CONTINUOS

       

- 1 TIME: 

       The recorded message plays only  
       Once
       

- CONTINUOS:

       The recorded message plays 
       continuously till the message 
       contact is kept closed.

25. SW

H MICROPHONE ALARM /  

      NORMAL THE MIXER COULD WORK 
      WITHOUT MICROPHONE CONSOLE  
      BMD6; A SIMPLE MICROPHONE BASE 
      WITH PRIORITY CONTACT COULD BE 
      CONNECTED TO XLR MICROPHONE 
      INPUT).

ITC

ITC

ITC

NOMENCLATURE AND FUCTIONS

7

4.2   REAR  PANEL

16

18

17

38

PRIORITY

TAPE

CD 

TUNER

MICRO

CONSOL

~240V/50Hz

T1AL250V

GAIN

GAIN

CONSOL
VOLUME

VOLUME

CHIME

OFF  

1

2

3  

     REC

MESSAGE

1 TIME  

CONTINUOS  

MESSAGE

NORMAL

ALARM

VOL.PLAY

   MESSAGE

VOL.REC

MIC

 OPEN  RELE  OUT

     ZONE 1  OUT

     ZONE 2  OUT

     ZONE 3  OUT

     ZONE 4  OUT

     ZONE 5  OUT

     ZONE 6  OUT

COM  NO1   NO2

PLAY  MESSAGE

+1

   
RELE  ZONE  CONSOL OUT         MIX  MUSIC-PAGE  OUT    MUSIC  OUT

     PAGE  OUT

IN   COM   ZONE

   +48V

PHANTOM

      +2      +3      +4      +5      +6

36

19

20

21

22

23

24 25 26 27

28 29 30

37

35 34 33 32 31

      

- ALARM: 

      The voice is simultaneously  
      distributed in all the 6 zones
      

- NORMAL:

      The voice is distributed only in the 
      zone selected with front panel 
      Buttons

26. VOLUME REC MESSAGE
27. VOLUME PLAY MESSAGE
28. PHANTOM POWER SELECT SW

H

29. CHIME VOLUME CONTROL
30. PRIORITY CONTROL PORT FOR BGM AND 
      INTERNAL CHIME.
31. INPUT RJ45 CONSOL

      Max 6 microphone bases in 
      Parallel

32. VOLUME INPUT CONSOL
33. CONSOL GAIN CONTROL
34. MICROPHONE GAIN CONTROL
35. MICROPHONE INPUT XLR BALANCED
36. AUDIO SOURCE INTERFACE
37. OUT ZONE (1~6)
38. OUT CONTACE OPEN RELE ZONE

      

ITC

T-6245

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISQUE DE CHOC ELECTRICUS 
-NE PAS QUVRIR

AVIS:

SERIAL  NO

:

PUBLIC ADDRESS  SYSTEM

Содержание T-6245

Страница 1: ...e OPERATION MANUAL DIGITAL MIXER 6 ZONE T 6245 MASTER 0 1 2 3 4 5 6 7 8 9 10 TREBLE BASS 0 1 2 3 4 5 6 7 8 9 10 MUSIC 0 1 2 3 4 5 6 7 8 9 10 MICRO REC STOP PLAY ACTIVE MIC MESSAGE RECORDER ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6 TUNER CD TAPE OUTPUT LEVEL POWER ON T 6245 DIGITAL MIXER 6 ZONE 0 5 5 4 3 2 1 4 3 2 1 0 5 5 4 3 2 1 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 OFF ...

Страница 2: ...AUTIONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 5 CONNECTIONS 8 6 APPLICATIONS 9 7 ADDRESS SET 11 8 BLOCK DIAGRAM 13 9 SPECIFICATIONS 14 10 DIMENSIONAL DIAGRAM 15 V1 0 2009 04 14 ...

Страница 3: ...r electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstable location...

Страница 4: ...oke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched on Loud noi...

Страница 5: ...H preamp output MUSIC MUSIC PAGE PAGE pre output 7 3 Classes priority a Build in record message 1and 2 Priority TUNER CD MP3 b Build in chime priority record message 1and 2 TUNER CD MP3 c Select paging MIC override all audio sources 9 Build in voltage output indicator 10 485 COM port 3 FEATURES T 6245 a digital mixer can provide an ideal public address solution from small to big places such us mos...

Страница 6: ...4 NOMENCLATURE AND FUNCTIONS 9 MUSIC Music volume control 10 MICRO MICRO volume control 11 REC Key switch Rec message Three messages of 60 seconds each could be recorded for message selection see sw h 13 on rear Panel 12 STOP Key sw h stop message 13 PLAY Key sw h play message for manual activation 14 ACTIVE Indicator play message 15 MIC Internal microphone for message recor ding itc itc itc MASTE...

Страница 7: ...VOLUME VOLUME CHIME OFF 1 2 3 REC MESSAGE 1 TIME CONTINUOS MESSAGE NORMAL ALARM VOL PLAY MESSAGE VOL REC MIC OPEN RELE OUT ZONE 1 OUT ZONE 2 OUT ZONE 3 OUT ZONE 4 OUT ZONE 5 OUT ZONE 6 OUT COM NO1 NO2 PLAY MESSAGE 1 RELE ZONE CONSOL OUT MIX MUSIC PAGE OUT MUSIC OUT PAGE OUT IN COM ZONE 48V PHANTOM 2 3 4 5 6 36 19 20 21 22 23 24 25 26 27 28 29 30 37 35 34 33 32 31 ALARM The voice is simultaneously ...

Страница 8: ...ID CONSOL LINE IN 0 10 1 2 3 1 GND 2 GND 3 24DC RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS SERIAL NO PUBLIC ADDRESS SYSTEM 8 1 2 3 4 5 6 7 8 B A B Network Line 240V 50Hz T1AL250V OPEN RELE OUT ZONE 1 OUT ZONE 2 OUT ZONE 3 OUT ZONE 4 OUT ZONE 5 OUT ZONE 6 OUT COM NO1 NO2 PLAY MESSAGE 1 RELE ZONE CONSOL OUT MIX MUSIC PAGE OUT MUSIC OUT PAGE OUT IN COM ZONE 2 3 4 ...

Страница 9: ...US NE PAS QUVRIR AVIS SERIAL NO PUBLIC ADDRESS SYSTEM POWER 24VDC 10 10 0 10 10 10 CHIME VOLUME TREBLE BASS VOLUME ID CONSOL LINE IN 0 10 1 2 3 1 GND 2 GND 3 24DC RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS SERIAL NO PUBLIC ADDRESS SYSTEM Compact disc Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 ZONE 6 OUT NO2 PLAY MESSAGE PRIORITY TAPE CD TUNER MICRO CONSOL GAIN G...

Страница 10: ...2 3 1 GND 2 GND 3 24DC RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS SERIAL NO PUBLIC ADDRESS SYSTEM POWER 24VDC 10 10 0 10 10 10 CHIME VOLUME TREBLE BASS VOLUME ID CONSOL LINE IN 0 10 1 2 3 1 GND 2 GND 3 24DC RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS SERIAL NO PUBLIC ADDRESS SYSTEM LINK OUT LINK OUT LINK OUT LINK OUT LINK OUT...

Страница 11: ...23 24 25 26 27 28 29 30 31 32 ADDRESS DEFINITION ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ADDRESS DEFINITION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ID CONSOL ADDRESS SET ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 11 T 6245 ...

Страница 12: ... 35 36 37 38 39 40 41 42 43 44 45 46 47 48 ID CONSOL ADDRESS SET ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 ADDRESS DEFINITION ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 12 T 6245 ...

Страница 13: ...4 V zone 4 OUT 24 V zone 3 OUT 24 V zone 2 OUT 24 V zone 1 OUT 24 V com OUT 24 V zone 6 OUT 24 V zone 5 OUT RELE ZONE CONSOL CONTACT 15 COLD GND HOT GND COLD COLD COLD COLD HOT HOT HOT GND GND GND HOT BALANCED RL1A RL2A OUT ZONE 1 CONTACT 21 OUT OPEN RELE CONTACT 20 OUT PAGE 0 dB CONTACT 19 OUT ZONE 2 CONTACT 21 OUT ZONE 3 CONTACT 21 LEVEL OUTPUT VU METER RL3B RL4B RL5B RL6B GND COLD GND HOT COLD ...

Страница 14: ... 40 20 000Hz 3dB CD input sensitivity impedance Frequency response S N ratio Control Bass 12dB 12dB 2 tone active for contact free in priority and BGM 0 1 Treble Normal distortion Chime Operating condition Main power supply 240 VAC 50 Hz 484X322X88 6 Dimension mm Max number of microphone bases Weight 6 58Kg Consol input Sensitivity 50 2 dB 2 5 500 mV S N ratio 68dB Frequency response 100 17 000Hz ...

Страница 15: ... 2 3 4 5 6 7 8 9 10 TREBLE BASS 0 1 2 3 4 5 6 7 8 9 10 MUSIC 0 1 2 3 4 5 6 7 8 9 10 MICRO REC STOP PLAY ACTIVE MIC MESSAGE RECORDER ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6 TUNER CD TAPE OUTPUT LEVEL POWER T 6245 DIGITAL MIXER 6 ZONE 0 5 5 4 3 2 1 4 3 2 1 0 5 5 4 3 2 1 4 3 2 1 ON OFF MASTER 0 1 2 3 4 5 6 7 8 9 10 TREBLE BASS 0 1 2 3 4 5 6 7 8 9 10 MUSIC 0 1 2 3 4 5 6 7 8 9 10 MICRO REC STOP PLAY ACTIVE...

Страница 16: ...PUBLIC ADDRESS SYSTEM 2009 04 Version1 0 ...

Отзывы: