background image

© 2012-2021 SOTA Instruments Inc. 

Page 1 of 14

|

 www.sota.com

The Silver Pulser

Model SP6 Manual

CONTENTS

WELCOME TO SOTA ..................................................................................................... 3 
BEFORE USING ............................................................................................................... 3
LEARN MORE ................................................................................................................. 3
COMPLETE UNIT INCLUDES ...................................................................................... 3
DO NOT USE .................................................................................................................... 4
MICROPULSING CAUTIONS ...................................................................................... 4
IONIC~COLLOIDAL SILVER CAUTIONS ................................................................. 5
GENERAL CAUTION ..................................................................................................... 5
SUMMARY OF LIGHTS ................................................................................................. 5
HOW TO USE THE MICROPULSING FUNCTION .................................................. 6

How Micropulsing Should Feel  ............................................................................... 9
Sensitive Skin ............................................................................................................... 9
Typical Use  ................................................................................................................ 10

HOW TO USE THE IONIC~COLLOIDAL SILVER FUNCTION ...........................10

How to Assemble ...................................................................................................... 10
How to Make Ionic~Colloidal Silver ...................................................................... 11
Typical Use ................................................................................................................. 12

ELECTRICAL SPECIFICATIONS  .............................................................................. 13

Power Requirements ................................................................................................. 13

Содержание Silver Pulser SP6

Страница 1: ...T USE 4 MICROPULSING CAUTIONS 4 IONIC COLLOIDAL SILVER CAUTIONS 5 GENERAL CAUTION 5 SUMMARY OF LIGHTS 5 HOW TO USE THE MICROPULSING FUNCTION 6 How Micropulsing Should Feel 9 Sensitive Skin 9 Typical U...

Страница 2: ...nc Page 2 of 14 www sota com The Silver Pulser Model SP6 Manual Optional Power Input 13 Output Specifications 13 TROUBLESHOOTING 14 COUNTRIES THAT PARTICIPATE IN MANUFACTURING 14 REPLACEMENT ACCESSORI...

Страница 3: ...he Silver Pulser is designed to be used independently but can also be used together with any of the SOTA Products With proper care your Silver Pulser should provide you many years of trouble free use...

Страница 4: ...e such as a pacemaker etc 2 As with all electrical products do not use near water when driving a car or when operating heavy equipment 3 Do not connect the Micropulsing Cord or the Silver Wire Holder...

Страница 5: ...he finger nails is usually an early sign The risk of argyria is considered greater for those who are ingesting incorrectly made Ionic Colloidal Silver and to a lesser degree those who are deficient in...

Страница 6: ...ve Rubber Probes to the Micropulsing Cord by gently sliding the Rubber Probes over the metal pins on the Micropulsing Cord as in image 2 Note Except to occasionally clean them the Rubber Probes can st...

Страница 7: ...the Cotton Sleeve will point down toward the elbow Press the sleeve to the Wrist Strap to firmly adhere the sleeve in place 6 Place the other Cotton Sleeve again with the open side towards the elbow...

Страница 8: ...itch counter clockwise until it clicks Do not force the ON OFF switch past its natural stopping point 17 Unplug the Micropulsing Cord Do not store the unit with the Micropulsing Cord plugged in as thi...

Страница 9: ...to be replaced The battery can continue to be used until the YELLOW light goes off Power Supply When Micropulsing as a safety feature the unit can only be powered by a 9 Volt battery Replacement Batte...

Страница 10: ...tes a day Increase gradually to a minimum of 2 hours each day Length of Use The SOTA Products User Guide available at www sota com spug offers suggestions for Focused Basic and Ongoing Wellness Plans...

Страница 11: ...to the water Keep them at least 25 mm or 1 inch from the bottom of the container 3 Turn the unit ON by rotating the ON OFF switch clockwise until it clicks It is not necessary to turn up the intensity...

Страница 12: ...ot freeze refrigerate or expose Ionic Colloidal Silver to extremes of temperatures as its potency may be affected Save on Batteries When making Ionic Colloidal Silver the unit can be powered by an AC...

Страница 13: ...le batteries it is suggested to take the unit with you to ensure the batteries will fit the enclosure To use a wall adaptor for making Ionic Colloidal Silver the output should be from 6 to 12 Volts DC...

Страница 14: ...t TROUBLESHOOTING Troubleshooting Guides for both the Micropulsing and Ionic Colloidal Silver functions of the Silver Pulser are available at www sota com manuals These Guides are a great tool to chec...

Отзывы: