- 27 -
SORHEA
G-FENCE
UG
UT
UR
UR
UR
UG
UR
UG
UR
UG
UG
UT
Gate
Not detector cable
/ 328 ft
/ 229 ft
/ 328 ft
100 m
/ 328 ft
100 m
/ 328 ft
/ 328 ft
/ 328 ft
/ 328 ft
100 m
70 m
30 m
/ 100 ft
100 m
100 m
100 m
100 m
2
SYSTEM DESCRIPTION
2.1 Principle
2.2 Detector cable
The detector cable integrates 40 sensors spaced at 3 m / 10 ft intervals to be installed on a
mesh fence.
2.3 Control Unit (UG)
The Control Unit (UG) analyzes and processes the data
from the detector cable(s).
Control Unit consists of:
The housing
The solar panel
The battery
The control card
The mounting hooks
2.4 Termination / Link Unit (UT/UR)
The Termination / Link Unit (UT/UR) can be used as Termination
Unit (UT) or as Link Unit (UR). Selection is made using a switch.
The Termination Unit (UT) allows termination of an open loop
installation.
The Link Units (UR) allow wiring of 2 detector cables between
themselves.
The Link Units (UR) must be installed systematically between
2 Control Units.
Detector cable
(Drum 40 sensors)
Sensor