– 13 –
SECTION 4
MECHANICAL ADJUSTMENTS
SECTION 5
ELECTRICAL ADJUSTMENTS
TEST MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and MW Auto Scan/Stop Level adjustments can
be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “power select” switch (S501) is “A (ON)” position.
2. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note:
Press the
[OFF]
button, if the clock is not displayed.
3. Push the preset
[4]
button.
4. Push the preset
[5]
button.
5. Press the preset
[1]
button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the
[OFF]
button.
2. Return the “power select” switch (S501) to initially set posi-
tion.
See the adjustment location from on page 16 for the
adjustment.
0 dB=0.775 V
Tape Speed Adjustment
Setting:
Speed checker
Frequency counter
–1.5 to +2.5%
2,955 to 3,075 Hz
TAPE DECK SECTION
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
reading on the speed checker or frequency counter becomes in
specification.
Specification: Constant speed
Adjustment Location: See page 16.
set
+
–
test tape
WS-48A
(3 kHz, 0 dB)
AUDIO OUT jack (J331)
10 k
Ω
speed checker
or
frequency counter
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idlers
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the power supply
voltage unless otherwise noted.
•
Torque Measurement
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 90 g
(more than 3.18 oz)
Reverse
CQ-403R
more than 90 g
(more than 3.18 oz)
•
Tape Tension Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
30 – 65 g•cm
(0.42 – 0.90 oz•inch)
Forward
CQ-102C
0.5 – 4.5 g•cm
Back Tension
(0.01 – 0.06 oz•inch)
Reverse
CQ-102RC
30 – 65 g•cm
(0.42 – 0.90 oz•inch)
Reverse
CQ-102RC
0.5 – 4.5 g•cm
Back Tension
(0.01 - 0.06 oz•inch)
FF, REW
CQ-201B
60 – 200 g•cm
(0.83 – 2.78 oz•inch)
Содержание XR-C5200
Страница 3: ... 3 SECTION 1 GENERAL This section is extracted from instruction manual ...
Страница 4: ... 4 ...
Страница 5: ... 5 ...
Страница 6: ... 6 ...
Страница 7: ... 7 ...
Страница 8: ... 8 ...
Страница 21: ...XR C5200 23 24 6 4 SCHEMATIC DIAGRAM MAIN Board 2 2 See page 30 for IC Block Diagrams Page 27 ...
Страница 23: ...XR C5200 6 6 SCHEMATIC DIAGRAM KEY Board See page 18 for Waveform 27 28 Page 24 ...