![Sony XDCAM PDW-700 Скачать руководство пользователя страница 156](http://html.mh-extra.com/html/sony/xdcam-pdw-700/xdcam-pdw-700_operation-manual_414516156.webp)
Menu List
156
Ch
apt
er 6 Men
u
Dis
p
la
ys
a
nd Det
a
iled
S
e
ttin
gs
20
AUTO
SHADING
AUTO BLK
SHADING
EXEC
Executes the auto black shading correction
function.
RESET BLK SHD EXEC
Clear black shading compensation values.
TEST OUT
SELECT
VBS
/Y/R/G/B/
LCD
Selects the signal output of the TEST OUT
connector.
MASTER
GAIN(TMP)
–6dB/–3dB/
0dB
/
3dB/6dB/9dB/
12dB/18dB/
24dB/30dB/
36dB/42dB
Temporarily sets the master gain value.
21
APR
APR
EXEC
Suppresses white flecks by executing the automatic
pixel noise reduction function.
APR(SLS)
EXEC
Suppresses white flecks in SLS (Slow Speed
Shutter) mode by executing the automatic pixel
noise reduction function.
Note
The execution time for this function is about 30
minutes. More time may be required when
temperatures inside the unit are low.
APR PRESET
EXEC
Deletes white flecks data that was added by
execution of the APR and automatic black balance
adjustment functions.
22
NETWORK
DHCP
ENABLE/
DISABLE
Selects whether to enable automatic acquisition of
the IP address from a DHCP server.
IP ADDRESS
xxx.xxx.xxx.xxx
192.168.1.10
Sets the IP address.
SUBNET MASK
xxx.xxx.xxx.xxx
255.255.255.0
Sets the subnet mask.
DEF.GATEWAY
xxx.xxx.xxx.xxx
0.0.0.0
Sets the default gateway.
LINK SPEED
AUTO
/10Mbps/
100Mbps
Sets the communications speed.
DUPLEX
AUTO
/FULL/
HALF
Sets the duplex mode.
No. Page
Item
Settings
Description