![Sony XCL5005 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/sony/xcl5005/xcl5005_technical-manual_418408051.webp)
Camer
a
Con
tr
o
l
Command
s
Parameter List
51
Parameter List
The following is the camera initial value parameter list.
*
PEDESTAL, RGAIN, GGAIN, BGAIN, BBALANCE,
and AUTO-DCLAMP are initialized to the factory setting
values by the setting initialization command INIT, but the
factory setting values cannot be given because they are
non-uniform camera-unique values and as such differ for
each camera.
Command
Parameter 1
Parameter 2
Parameter 3
Explanation
GAIN-STEP
0
–
–
Gain-step setting
GAIN-FINE
0
–
–
Gain-fine setting
PEDESTAL
[Unique value of
camera]
*
–
–
Pedestal level setting
WBMODE
0: 3200 K
–
–
White balance mode setting
PIXEL-GAIN
ON
–
–
Pixel gain setting
RGAIN
[Unique value of
camera]
*
–
–
Manual R gain setting
GGAIN
[Unique value of
camera]
*
–
–
Manual G gain setting
BGAIN
[Unique value of
camera]
*
–
–
Manual B gain setting
BBALANCE
[Unique value of
camera]
*
–
–
Black clamp level setting
RCORR
0
–
–
RGB red correction setting
GCORR
0
–
–
RGB green correction setting
BCORR
0
–
–
RGB blue correction setting
DGAIN
0 (OFF)
–
–
Digital gain mode setting
DGAIN-STEP
0
–
–
Digital gain-step setting
DPEDESTAL
0 (OFF)
32
–
Digital pedestal setting
AUTO-DCLAMP
ON
[Unique value of
camera]
*
–
Automatic clamp control setting
ADC-COEF
208
–
–
Automatic clamp control correlation
factor
DCLAMP
0 (OFF)
–32
–
Digital clamp level setting
SHUTTER
0
–
–
Shutter speed setting
TRG-MODE
0 (OFF)
–
–
Trigger mode setting
TRG-POL
1: Positive polarity
–
–
External trigger polarity setting
TRG-OVLP
0 (OFF)
–
–
Trigger overlap mode setting
DTL-MODE
0 (OFF)
–
–
DTL mode setting
DTL-COEF
8
–
–
Edge enhancement filter factor setting
IMG-WIZE
0: 12 bit
–
–
Image data width setting
IMG-TAP
0: 80 MHz 1TAP
–
–
Image data tap setting
GAMMA-MODE
0 (OFF)
–
–
Gamma mode setting
FILTER-MODE
0 (OFF)
–
–
Filter mode setting
BINARIZE
0 (OFF)
1911
–
Binarization mode, Binarization
threshold value setting
BINNING
0 (OFF)
–
–
Binning mode setting
PARTIAL
0 (OFF)
0
0
Partial scan setting
PARTIAL-OFFSET
38
–
–
Partial scan offset setting
HPARTIAL
OFF
2000
–
Horizontal partial scan setting
EXTTRG
0: DIGITAL IF
connector
–
–
External trigger signal input selection
COLORBAR
0 (OFF)
–
–
Color bar output setting
GRAYSCALE
0 (OFF)
–
–
Grayscale output setting
FLIP-FLOP
0 (OFF)
–
–
Flip-flop output setting
WEN-STRB
0: GND output
–
–
DC IN connector signal output setting
BRATE
2: 38400 bps
–
–
Serial communication speed setting