![Sony XCL-V500 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/sony/xcl-v500/xcl-v500_technical-manual_1322933039.webp)
39
Functions of the XCL-V500
XCL-X700/V500
Input/Output Signal Specifications
■
External-HD/VD input phase specifications
Input External-HD/VD signals that meet the
specifications indicated above.
Falling edge of External-VD:
Input the falling edge of External-VD signals within
100 CLK earlier or later, with the falling edge of the
External-HD signals as a reference.
These input phase specifications apply to all Camera
Modes except for Trigger Mode2.
Rising edge of External-VD:
Input the rising edge of the External-VD signals within
5 CLK earlier or 100 CLK later, with the falling edge
of External-HD signals as a reference.
These input phase specifications apply to High-rate
scan I in Restart/Reset Mode.
Notes
• The falling edges of Internal-HD/VD signals fall in
neatly with the falling edges of External-HD signals.
LVAL/FVAL signals are output 11 CLK later, with
the falling edges of External-HD signals as a
reference. FVAL signals are output 1H later than that
for External-HD signals in Restart/Reset Mode and
Trigger Mode1.
• Be aware that the camera module automatically
detects external synchronization only when External-
HD signals meeting the input specifications are input.
• The input phase specifications above apply to both
the 12-pin connector and the digital interface
connector.
• To operate the camera module in the Normal Mode
with external synchronization, input External-VD
signals with a 525H interval.
To operate the camera module in the Normal Mode
with external synchronization with the Binning
function on, input External-VD signals with a 263H
interval.
Reference
Phase Point
External-HD
Rising Edge of
External-VD
Falling Edge of
External-VD
5CLK
100CLK
100CLK
100CLK
1CLK=40.74 ns