Came
ra
Co
nt
rol
Comman
d
s
Command Form
40
Camera Control Commands
Command Form
When inputting commands, separate a command and a parameter by a space, and press [Enter] to confirm. Upper/lower
case characters are not distinguished. Input format and an input example are shown below.
Input format:
Command Param1 param2 param3 Param4 [Enter]
Input example:
ROI 640 480 8 6 <CR>
Command Input and Response
Camera echoes back against characters (alphabetic, numeric), space, backspace and Enter; otherwise, other invalid
characters are ignored. When a command is successfully completed, the status will be echoed.
Input:
Gain 6<CR>
Output:
OK<CR>
Status
Explanation (Example)
OK
Successfully completed
ERROR: Invalid argument number.
The argument number of the parameter is invalid.
(Width 100 100)
ERROR: Invalid parameter.
The parameter is invalid.
(Width abc)
ERROR: Not implemented.
The command is not supported.
(Vbin of a color camera)
ERROR: Access denied.
Commands are limited.
(A trigger mode related command is controlled by SP-TRG-MODE=1.)
ERROR: Busy
The command cannot be received.
SYNTAX ERROR!
The command is not correct.
(Widtt 100)