30
Trigger source
This can be input via the DC IN connector or software command (TriggerSoftware). Refer to “Trigger Signal Input”
(page 12) for details.
Notes
• The trigger sources when operating the special trigger and the trigger mode are separately defined.
• The PTP cannot be selected in the special trigger mode.
Trigger inhibition
Trigger input can be disabled. This function is effective when disabling the trigger signal to a specific camera in the
environment where multiple cameras are connected by the same trigger signal and when preventing false operations
caused by noise contamination to the trigger signal line (due to the installed environment).
Trigger delay
The camera can delay the trigger signal.
Trigger counter
Accepted triggers by which video output is performed are counted. Triggers are counted up by the internal counter even
in the free-run operation. Setting 0 resets the counter. Video output is not performed for triggers that coincide with the
double exposure timing, but triggers are counted up. Triggers that have been removed by trigger range limit are not
counted. The trigger counter returns to 0 when the upper limit (2147483647) is reached. The trigger counter can return
to 0 by writing 1 to the TriggerCounterReset register.
Register
Parameter
Setting
TriggerInhibit
Off (0)
Trigger is accepted
On (1)
Trigger is not accepted
Register
Parameter
Setting
TriggerDelay
0 to 4000000
Trigger delay [µs]
Register
TriggerCounter
TriggerCounterReset
Trigger signal
Trigger inhibition
Exposure
Trigger
disabled
Sensor output
Trigger signal
Exposure
Sensor output