background image

Operating Instructions

3-206-174-21 (1)

Film Scanner

UY-S100

© 2001 Sony Corporation

Содержание UY-S100

Страница 1: ...Operating Instructions 3 206 174 21 1 Film Scanner UY S100 2001 Sony Corporation ...

Страница 2: ...suant to Subpart B of Part 15 of FCC Rules Description of signal words WARNING Used for the critical situation which may possibly cause a death or serious injury if the situation is not avoided CAUTION Used for the critical situation which may possibly cause a slight injury or a medium degree of injury if the situation is not avoided This word is also used for the critical situation under which a ...

Страница 3: ...hat of the appliance should be used Cords rated for less amperage than the appliance may overheat 7 Always unplug appliance from electrical outlet before cleaning and servicing and when not in use Never yank cord to pull plug from outlet Grasp plug and pull to disconnect 8 Let appliance cool completely before putting away Loop cord loosely around appliance when storing 9 To reduce the risk of elec...

Страница 4: ...tware licence agreement 1 Warranty booklet 1 Notes Retain the original carton and packing materials in case you have to transport the unit in the future Remove the carrier when transporting the Film Scanner The optional UYA S77TR film tray cannot be used with this unit Use the supplied film tray only Checking the Package Film carrier 1 Slide carrier 1 Carrier cover 1 Halogen lamp 1 Film tray 1 SCS...

Страница 5: ... Loading the Film in the Carrier 14 Loading a sleeve film into the carrier 14 Loading a slide into the carrier 14 Loading an IX240 cartridge film into the carrier 15 Turning the Power ON OFF 16 Maintenance Checking and Other Information Precautions 17 About the conditions of film ends and remedies 17 On safety 19 On installation 19 On heat build up 19 On cleaning 19 On repacking 19 Maintenance 20 ...

Страница 6: ...lm or IX240 film The following shows the available resolution modes and the number of scanned pixels when 135 film is scanned in the normal cropping mode LD low definition 384 256 pixels SD standard definition 768 512 pixels HD high definition 1 536 1 024 pixels UD ultra definition 3 072 2 048 pixels Note The number of scanned pixels differs according to the film type and cropping mode panorama sl...

Страница 7: ... To avoid injury do not insert your hand or fingers into the movable area of the carrier Location and Function of Parts and Controls Introduction 1 POWER switch and indicator green Press to turn the Film Scanner on or off The indicator lights up while the power is ON 2 BUSY indicator green Lights while the Film Scanner is in operation 3 ALARM indicator orange Lights when a problem occurs 4 Carrier...

Страница 8: ...device may be damaged Notes Connect the AC power cord last For details about connections of computer consult its manual as well Hooking Up Connect to either of two SCSI connectors SCSI cable not supplied to SCSI to AC IN AC power cord supplied to AC outlet UY S100 Film Scanner DIP switch See page 10 To remove Computer Ferrite filters supplied To connect the SCSI cable SCSI cable clamp supplied See...

Страница 9: ...he supplied ferrite filters near the connectors at both ends of the cable See the figure on page 8 To attach the ferrite filters release the lock of the ferrite filter with a screwdriver or a similar tool pass the cable through the ferrite filter and lock the filter in place Attaching the supplied SCSI cable clamp To secure the SCSI cabling use the supplied SCSI cable clamp Attach the SCSI cable c...

Страница 10: ... shown below Note Turn off the power before changing the DIP switch setting TERMINATOR ON OFF setting ON If the scanner is located at the end of the SCSI bus this switch should be set to ON The internal terminator is ON OFF If another device is at the end of the bus this switch should be OFF SCSI ID setting The SCSI ID selection must be different from any other device on the bus If two SCSI ID dev...

Страница 11: ...so stored in the CD ROM When using the scanner for the first time Before starting operation install the scanner driver porgram and perform required setup For details read the README file in the CD ROM Updating the driver program and firmware You can download the updated driver program and scanner firmware via the Internet Access the following site http www sony co jp en Products DP driver index ht...

Страница 12: ...r 135 film Film carrier supplied Sleeve film Film with more than three frames 135 film IX240 film Slide carrier supplied Slides mounted UYA S90SF auto slide feeder optional IX240 cartridge film IX240 film carrier optional The length of three frames should be more than 114 mm or 4 1 2 in 38 mm or 1 1 2 in 3 A film with a length of less than 114 mm or 4 1 2 in cannot be scanned ...

Страница 13: ...nner and fold down the handle to lock Then close the carrier cover Note Be sure to close the carrier cover and lamp cover If either cover is open prescanning and scanning cannot be performed Also opening the cover during prescanning or scanning stops the operation Removing the carrier Press the handle to unlock and lift the carrier Mounting Removing the Carrier Lamp cover Carrier cover ...

Страница 14: ...otes If the film contains a transparent portion such as an exposed area of positive film the film cannot be fed properly Cut off the transparent portion The curling condition of the sleeve film and film ends may cause feeding error Fix the film correctly before inserting it into the carrier For details see About the conditions of film ends and remedies on page 17 Loading a slide into the carrier I...

Страница 15: ...is removed If you insert a cartridge with its tab intact or not removed completely Not processed film is in this cartridge Please remove the cartridge appears on the screen In this case make sure that the cartridge film is processed and remove the tab completely Then insert the cartridge film again Do not touch the carrier or open the lid of the cartridge holder during prescanning or scanning This...

Страница 16: ...zation is completed the BUSY indicator goes out and the POWER indicator remains lit in green Note If any trouble occurs when the power is turned on the ALARM indicator remains lit in orange In this case check if the carrier carrier cover and lamp cover are mounted correctly page 13 Turning off the power of the Film Scanner Press the POWER switch for two seconds or more until the green POWER indica...

Страница 17: ...itions of film ends and remedies Reroll in the opposite direction of the curl Reroll in the direction of protrusion of the curls More than 5 mm or 3 16 in Curling conditions Film ends conditions In order to avoid feeding errors of the sleeve film in the film carrier check the curling condition of the film and film ends before inserting it into the film carrier Please fix the following before inser...

Страница 18: ...Space between perforations is broken Film ends conditions Perforation conditions If there is enough space between the broken perforation and the image area cut the broken portion If there is not enough space cut it off diagonally If there is enough space between the taped portion and the image area cut the taped portion If there is not enough space peel off the tape completely Less than the mark w...

Страница 19: ... to the unit When you first install the unit or when you move it from a cold to a warm location wait for a while before operating the unit On heat build up Heat builds up in the unit if it is used for an extended period of time If this occurs allow the unit to cool down On cleaning To keep the unit looking brand new periodically clean it with a mild detergent solution Never use strong solvents suc...

Страница 20: ... causes film misfeeding We recommend that you clean the rubber rollers once a day Note Use alcohol for cleaning the rubber rollers only Do not use it for cleaning other portions Cleaning cabinet When the cabinet becomes dirty wipe it with a close moistened with water or neutral detergent dissolved in water Do not use benzene alcohol thinner or chemical cloth as they may damage the finish Maintenan...

Страница 21: ...oved the packing materials Check if the halogen lamp is burned out page 7 Scanned image appears strange Check if you applied force to the carrier Remove the carrier and mount it again Check the halogen lamp is turned on Blocking the ventilation holes may cause the lamp to turn off Check if you applied vibration to the unit during scanning Check if the halogen lamp is burned out page 7 If you are u...

Страница 22: ... max with maximum input load at 220 V AC Operating temperature 5 35 C 41 95 F Operating humidity 30 85 RH Dimensions Main unit 280 148 431 mm w h d 111 8 57 8 17 inches not including connectors on the rear Film carrier 201 110 58 mm w h d 8 43 8 23 8 inches not including projecting part Slide carrier 232 96 40 mm w h d 91 4 37 8 15 8 inches not including projecting part Mass Main unit Approx 9 8 k...

Страница 23: ...23 ...

Страница 24: ...Sony Corporation ...

Отзывы: