Display of Standby/Timer LED Flash Count
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
2 times
4 times
5 times
Diagnostic Item
Flash Count*
+B overcurrent
2 times
Vertical deflection stopped
4 times
White balance failure
5 times
*One flash count is not used for self-diagnostic.
Stopping the Standby/Timer LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER LAMP from
flashing.
Self-Diagnostic Screen Display
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confirmed, it is
possible to bring up past occurrences of failure on the screen for confirmation.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:
Display
Channel 5
Sound volume
Note that this differs from entering the service mode (sound volume
).
Power ON
+
Self Diagnostic Screen Display
SELF DIAGNOSTIC
2:
3:
4:
5:
101:
N/A
N/A
0
0
0
1
0
Numeral “0” means that no fault was detected.
Numeral “1” means a fault was detected one time only.
Handling of Self-diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during
repairs. When you have completed the repairs, clear the result display to “0”.
Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after completion
of the repairs.
Clearing the Result Display
To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed,
as shown below:
ENTER
Channel 8
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
STANDBY/TIMER LED