– 22 –
KV-1499XF
RM-952
3-2. CONVERGENCE
Preparation :
•
Before starting this adjustment, adjust the focus, horizontal size
and vertical size.
•
Minimize the brightness setting.
•
Provide dot pattern.
(1)
Horizontal and Vertical Static Convergence
(Moving vertically), adjust the V.STAT magnet so that the red, green
and blue dots are on top of each other at the center of the screen.
R G B
G
R
B
Center dot
C3 board
RV 702
V.STAT Magnet
H. STAT VR
4
BMC (Hexapole) Magnet.