Note
Characters or marks in some languages may not be displayed.
[227] Adjusting Settings
Reverting to the factory default settings
You can clear all memorized settings and restore the receiver to the factory default settings by
the following procedure. This procedure can also be used to initialize the receiver before you
use it for the first time.
Be sure to use the buttons on the receiver to perform this operation.
Note
It takes a few minutes for the memory to be cleared completely. Do not turn the receiver off until
[CLEARED !] appears on the display panel.
[228] Troubleshooting
Error messages
PROTECTOR
The receiver will automatically turn off after a few seconds. Check the followings:
There may be an electrical surge or power failure. Unplug the AC power cord (mains lead)
and then plug in the cord again after 30 minutes.
The receiver may be covered and the ventilation holes are blocked. Remove the object
covering the ventilation holes of the receiver.
The impedance of the connected speakers may be below the rated impedance range
indicated on the back panel of the receiver. Connect speakers whose impedance falls within
the range.
Unplug the AC power cord (mains lead) and let the receiver cool down for 30 minutes while
performing the following troubleshooting:
Disconnect all of the speakers and subwoofer.
Check that the speaker wires are tightly twisted on both ends.
Connect the front speaker first, increase the volume level and operate the receiver for at
least 30 minutes until it completely warms up. Then, connect each additional speaker
one by one and test each additional speaker until you detect which speaker is causing
the protection error.
[PURE.DIRECT] appears on the display panel when the Pure Direct function is activated.
*2
Stream information may not be displayed.
*3
Turn off the receiver.
1
Hold down
(power) on the receiver for 5 seconds.
[CLEARING] flashes on the display panel for a while, then changes to [CLEARED !].